Page 23
ENGLISH
Installation and Operation Manual
|
Jandy
®
LXi
™
Model Pool and Spa Heater by Zodiac
®
8. With a permanent marker, place a mark on the
adapter so that the mark faces the same direction
as the water connections on the header.
9. Remove the adapter from the hole.
10. Coat the threads of the pressure relief valve
(PRV) with an appropriate metal to metal thread
sealant.
11. Install the adapter on the PRV and tighten using
two (2) wrenches. Use the mark made earlier on
the adapter to orient the PRV to the desired direc-
tion in relation to the water connections on the
header.
12. Wrap the threads of the adapter with a suitable
teflon thread tape.
13. Reinstall the adapter, with the PRV, into the plas-
tic threaded hole and tighten it until the mark on
the adapter is once again facing the same direc-
tion as the water connections on the header.
CAUTION
Do not use any pipe compound or pipe dope on
the threads of the adapter or any part that comes in
contact with the plastic headers. These compounds
may damage the header over a period of time.
ATTENTION
N’utilisez ni pâte à joint ni pâte lubrifiante sur le
filetage du raccord intermédiaire ou sur toute pièce
qui entre en contact avec le tuyau collecteur. Ces
produits risquent d’endommager le tuyau après un
certain temps.
CAUTION
In order to prevent property damage, do not over-
tighten. Overtightening may crack the header.
ATTENTION
Afin d'empêcher des dégâts matériels, ne serrez
pas trop. Le serrage excessif peut provoquer des
fissures dans la tête.
DO NOT TIGHTEN WITH A WRENCH.
Overtightening may crack the header. Route the
discharge piping so that discharge from the pipe does
not endanger anyone near the heater. Refer to your
local installation codes for more detailed information.
The valve setting should be at or below the maxi-
mum working pressure of any component in the filter
system. The maximum working pressure of the LXi
heater is 75 psig.
5.7
Auxiliary Components,
Chlorinators, Ozone Generators,
and Sanitizing Chemicals
The LXi heater is manufactured with materials
that are not compatible with high concentrations of
ozone, chlorine, bromine, or other sanitizing chemi-
cals. Heater damage caused by excessive chemicals
or improper ozonization is not covered by the Zodiac
Pool Systems, Inc., warranty. Be sure to adhere to the
following:
•
When ozone is injected upstream of the heater,
install an offgas mixing chamber, or an ozone
bypass system between the heater and the ozone
injector to prevent ozone and air from entering
the heater.
•
When chemical feeders are used, plumb the feed-
er downstream of the heater and install an in-line
check valve between the heater and the feeder
(a minimum of 18 inch is required between the
heater and the check valve).
•
Wire any electrical chemical feeder so that it
cannot operate unless the filter pump is running.
If the feeder has an independent clock control,
synchronize it with the filter clock.
•
Never deposit chemicals directly in the pool
skimmer.
Section 6. Electrical
WARNING
ELECTRICAL SHOCK HAZARD.
This heater con-
tains wiring that carries high voltage. Contact with
these wires may result in severe injury or death.
AVERTISSEMENT
POSSIBILITÉ DE CHOCS ÉLECTRIQUES. Ce
système de chauffage contient du filage de haut
voltage. Un contact avec ces fils peut résulter en
des blessures sérieuses ou la mort.
CAUTION
Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and
dangerous operation.
Verify proper operation after servicing.
ATTENTION
Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des
erreurs de câblage peuvent entraîner un fonc-
tionnement inadéquat et dangereux.
6.1
General Information
Wiring connections must be made exactly as
shown in the wiring diagram found on the inside of the
heater door. See Figure 20. The heater must include a
definite means of grounding. There is a bonding lug on
the right side of the heater, where a bond wire must be
attached.
6.2
Main Power
Electrical wiring must be in accordance with the
latest edition of the National Electric Code (NEC),
ANSI/National Fire Protection Association
®
(NFPA)
70, unless local code requirements indicate otherwise.
The heater comes factory-wired intended for
use with 240 Volt, 60 Hz AC field electrical supply.