16
b
c
d
e
f
g
i) Fill the cover connection with grease (ref. W0265A).
j) Position the stuffing box on the cover. The cable should be able to move freely in the
stuffing box.
k) Insert the two 4.2x13 screws.
l) Use a 19mm spanner to tighten the stuffing box until the seal is flush with the top of the
cover.
m) Refit the rotor on to the pump motor shaft.
n) Insert the motor unit into its housing. Take the excess cable to the outside of the housing.
o) Secure the motor unit to its housing with the four 5x12 screws. Make sure the rotor is
properly centred in the flow guide and not rubbing.
p) Refit the cable clamp to the housing.
i
k
l
To complete the assembly, first fit the cable-side track plate (see para. 2.8.4.), then the plate on side
opposite the cable (see para. 2.7.7)
. Fit the handle
(lowest float on the cable side)
, the motor unit
protective screen and the bumpers.
Содержание INDIGO
Страница 17: ...17 3 TECHNICAL DIAGRAMS 3 1 GENERAL DIAGRAM...
Страница 18: ...18 3 2 TROLLEY W1210A...
Страница 19: ...19 3 3 MOTOR UNIT W1287A...
Страница 21: ...21 3 4 CONTROL UNIT W1207A...
Страница 22: ...22 3 5 HOUSING W1286A...
Страница 27: ...27 3 10 FILTER HOLDER W1201A NOT INCLUDED IN THE W1201A ASSEMBLY...