4
Installation advised:
X = Y: minimum 15 to 20 cm
Note 1:
advised fitting to retain water permanently in the exchanger body.
Note 2:
advised fitting to avoid aggressive chlorine feedback into the heater when the filtering is stopped
4.2 Electric connections
• The single-phase electrical supply (230V-50Hz) of the exchanger must come from a protection and
switching device (not supplied) complying with the standards and regulations in force in the country
where it is installed (in France, refer to standard NF C 15100).
• use the supply cable delivered with the appliance: 2 poles + Earth 10/16 A in 3G1 (section 1 mm²).
Do not admit any long extension or multisocket connection.
Remark:
Plan for a socket to connect the supply cable delivered with the appliance.
• Electrical protection: this current socket must have a 5 A fuse switch with, upstream, a 30 mA
differential circuit breaker (calibre > than 5 A), or an
independent
30 mA circuit breaker (calibre 5 A)
upstream.
Connection Heatline in case exchanger
Note
:
• The acceptable voltage variation during operation is ± 10%,
• electric cables shall be fixed.
Electric box
Filtration electric box
230V-1N-50Hz-~-
Single-phase Main supply n Earth
Heat Line in case
E
S
Heatline in case
Water treatment
X
Y
HYDRAULIC CONNECTIONS
Pool water filtration circuit
Primary circuit
House heating circuit
Automatic air bleed
Check valve
Circulating pump
Pressure valve
Valves
Expansion vessel
Gas or Fuel-oil boiler
Aquastat
House
heating
House heating
circulation pump
TO RADIATORS
E
= From pool
S
= To pool
Filter
Pump
Water treatment
Caution! Connections of primary circuit shall be
realised before any valve or pump.