13
2.5.2 Identi fying the functi ons to be connected
Terminal
block
messages
Type
Cable
clamp
Functi ons
eXO® (iQ)
GenSalt OT
With pH Link or
Dual Link
SENS
Input
-
Connecti on for the control board
for pH Link and Dual Link modules
/
/
PUMP
Input
-
Connecti on for the pH regulati on pump
for pH Link and Dual Link modules
/
/
CELL
Output
1
Connecti on for the electrolyti c cell
UI
Output
-
Connecti on for the display
TEMP
Input
3
Connecti on for the temperature sensor
/
Flow
Input
2
Connecti on for the fl ow switch
iAL RS485
Input
4
Functi on not used – do not wire
/
/
/
VSP RS485 Output
5
Connecti on dedicated to controlling the
Zodiac® variable-speed fi lter pump
/
/
-
Functi on not used – do not wire
/
/
/
COVER
Input
7
Connecti on for the roller shutt er/cover for
automati cally managing the LOW functi on
SLAVE
Input
8
Connecti on for an external appliance for the
ON/OFF control of the chlorinator (automati c
regulati on, etc.)
/
AUX 2 12-
24V
Output
9
Connecti on dedicated to the ON/OFF control
of a
low-voltage
device. Connecti on used to
control a heati ng system. This connecti on
does not power the device: it manages the
ON/OFF functi on.
AUX 1 230
V
Output
10
Connecti on dedicated to the ON/OFF control
of a
high-voltage
device. This connecti on
does not power the device: it manages the
ON/OFF functi on.
/
PUMP
230V
Output
11
Connecti on dedicated to the power supply to
the pool fi lter pump.
MAINS
Input
12
Mains power supply to the appliance
110-240 VAC - 50/60 Hz
: Connecti ons made during manufacture
: Mandatory connecti ons to be made
: Functi on to be connected (opti onal)
EN