5. Loosely coil the power cable starting at the
cleaner and moving toward the connection
point at Control Unit. Store the cable by
wrapping it around the hook located on the
front of the caddy.
Figure 24. Untangle the power cable
Replacing Wear Parts
Replacing Brushes
The cleaner is fi tted with PVC brushes with a
''wear'' indicator.
raised groove becomes
partially flattened,
indicating excessive
wear
Figure 25. Worn Brush Indicator
To maintain cleaner performance at its best you
need to replace the brushes as soon as one of the
wear indicators is reached (even if the blade wear
is not even). It is recommended that you replace
the brushes when the rubber is worn down to
the top of the wear indicator (or every two years,
whichever comes fi rst).
To replace a worn brush:
1. Stand the cleaner on its end in a vertical
position (Figure 26).
Figure 26. Cleaner in Upright Position
2. Separate the edges of the brush and undo
the tabs. Remove the worn brush (Figure
27).
Figure 27. Undo the Tabs of the Brush
3. Position the new brush underneath the
roller with the spikes facing downwards
(Figure 28).
Page
18
Zodiac
®
Duo-X
™
Robotic Pool Cleaners
|
Owner's Manual