background image

 

5 /10 

 

 E 
 N 
 G 

  

  

 S 
 H 

 
 
 

INFLATION SYSTEM 

 

 

THE FOOT PUMP

 

 

 
 
 

a. connecting tip 
b. hose end piece 
c. hose base 
d. outlet for inflation

 

 

a

b

c

d

 

 

THE STANDARD VALVES 

 

(

1

) cap    (

2

) valve insert    (

3

) base

 

 
To  activate  the  standard  valves  into  INFLATION 
position: 

  Free the valve insert from its protection. 

  Unscrew the valve cap. 

  Screw the valve insert onto its base (screw it tight 

but  without  exaggeration,  not  to  deteriorate  the 
screw  thread)  and  check  that  the  valve  cap 
remains accessible. 

 

To deflate:

 

 

Unscrew the valve insert from its base 

1

2

3

 

 

SEMI BUILT-IN VALVES 

 

To activate the semi built-in valves:

 

 

 

in inflating position

 

in deflating position

 

 

 

 

 

 

Push and turn the knob one-

quarter of a turn 

The membrane is closed, the knob 

is up 

The membrane is open, the knob is 

down 

 

NOTE: 

NEVER 

TIGHTEN 

TOO 

MUCH: 

YOU 

COULD 

UNSCREW  THE  ENTIRE  INTERNAL  INFLATION 

SYSTEM OF THE VALVE

 

 

 

Содержание CLASSIC MARK 1

Страница 1: ...PROCEDURE OF THE BOAT AND ITS EQUIPMENT VOLUME 2 TECHNICAL SPECIFICATIONS ASSEMBLY PROCEDURE ZODIAC CLASSIC MARK 1 MARK 2C MARK 2 CONTENTS Page Page Assembly procedure 2 Pressure 8 Check on unpacking...

Страница 2: ...Y 5 Finish inflation of the boat to the correct pressure 7 INFLATING THE BOAT 8 PRESSION 6 Install equipment V VI ASSEMBLY OF EQUIPMENT CHECK ON UNPACKING ATTENTION DO NOT USE A SHARP TOOL CUTTER KNIF...

Страница 3: ...on fig 1 4 Fit all sections together fig 1 5 Position sections 3 and 4 as an apex in a tent like position fig 1 and 2 6 Check that all sections are correctly aligned fig 4 7 Flatten the apex by standi...

Страница 4: ...4 10 ASSEMBLY fig 1 A fig 1 B a floorboard b buoyancy tube c angle d bottom fig 2 1 5 4 2 3 6 fig 3 fig 4 7 8 1 2 3 4 5 7 9 a b c d...

Страница 5: ...rt onto its base screw it tight but without exaggeration not to deteriorate the screw thread and check that the valve cap remains accessible To deflate Unscrew the valve insert from its base 1 2 3 SEM...

Страница 6: ...6 10 INFLATION SYSTEM PRESSURE INDICATOR...

Страница 7: ...aler 1 INFLATING THE BUOYANCY MECHANISM Place the adapter corresponding to the diameter of the semi built in valve at the inflator pipe nozzle Inflate the buoyancy mechanism balancing the pressure bet...

Страница 8: ...ch it temperature 20 C the temperature and internal pressure of the inflatable compartments will drop simultaneously up to 120 mb and YOU WILL THEN NEED TO REFLATE until you regain the millibars lost...

Страница 9: ...9 10 E N G L I S H...

Страница 10: ...rage 6 Fold in the 2 sides of the main buoyancy tube A fold the cones onto the transom then roll up the boat around the transom C Start again if you feel there is still some air left in the tubes A B...

Отзывы: