ZoDiac Believes in safetY first

ZoDiac Believes in safetY first

We take safety seriously.  Always exercise caution when using 
electrical appliances and follow the instructions. Failure to do so 
could result in permanent injury, electrocution or drowning.

General WarninGs

MagnaPool is designed for swimming pool use only. Contrary use 
could affect performance and void warranty. 
Operating without water flowing through the cell may cause a build 
up of flammable gases, resulting in fire or explosion.
Keep equipment out of reach of children.
A damaged supply cord should only be replaced by the 
manufacturer, authorized service agent or electrician. 
When installing and using this electrical equipment, always follow 
basic safety precautions.
Before performing installation, disconnect all power. 
For swimming pools,  Australian standards recommend that a 
suitable level of sanitizer must be maintained at all times (check with 
your local pool shop for more information).
Service to equipment should only be carried out by qualified and 
authorized pool professionals.

Содержание MagnaPool

Страница 1: ...Installation and Operator Guide...

Страница 2: ...Part Qty Description a 1 MagnaPool Control Centre b 1 Hydroxinator cell c 1 Power pack bracket d 2 Reducing bushes This Kit Contains...

Страница 3: ...The MagnaPool innovation in water science is providing therapeutic and environmentally friendly mineral water for homes and commercial pools around the world Let our water science and our wellness ph...

Страница 4: ...up of flammable gases resulting in fire or explosion Keep equipment out of reach of children A damaged supply cord should only be replaced by the manufacturer authorized service agent or electrician...

Страница 5: ...result in personal injury and or damage to the cell One pump per electrical socket only no ancillary equipment should be connected to the same outlet This appliance is not intended for use by persons...

Страница 6: ...your pool safe from any bacteria or viruses thereby providing you with a beautifully safe swimming environment PLEASE NOTE The cell should always be the last device placed on the water pipe In the ret...

Страница 7: ...Turn UI power on off Up Down Scroll up down within current menu to highlight a specific menu command Menu Back Enters into the main menu and used to go back to previous menu Select Enter Select enters...

Страница 8: ...er on 2 Wait for the start up sequence to complete 3 Press the button to enter the MAIN MENU 4 Use buttons and scroll to SET CLOCK 5 Press 6 Use buttons to set the hours 7 Press to save the hours 8 Us...

Страница 9: ...the system on and off as required During swimming season consider running the system for around 8 hours a day This can be increased to 10 hours during periods of very hot weather In winter it may onl...

Страница 10: ...ress to select the timer you wish to set Timer 1 or Timer 2 5 Press 6 Press to set the hours on time 7 Press to save the hours 8 Press to set the minutes on time 9 Press to save the minutes 10 Press t...

Страница 11: ...Clock At times it may be desirable to control the system using an external time switch If the system is turned ON and the external timer fails to switch the mains power off within 30 hours the system...

Страница 12: ...the reading over time will help ensure optimum output You will need to manually gauge the required output based over a number of weeks observation and testing A good guide is around 70 80 when in swim...

Страница 13: ...00 ppm at 27 C To increase Add chlorine or increase output of equipment Add buffer or soda ash sodium carbonate Add sodium bicarbonate Add calcium chloride Add Cyanuric acid Add Minerals To decrease A...

Страница 14: ...ng the Controller To be done before making a wiring connection 1 Switch power to the unit on 2 Wait for the start up sequence to complete 3 Press the button 4 Press the button to scroll down to CONTRO...

Страница 15: ...any wiring connections disconnections ensure mains power is removed from both the controller and the MagnaPool Control Centre When connected to a controller the MagnaPool Control Centre acts as the s...

Страница 16: ...iagram The wiring colour codes are outlined below Depending on the make of the Controller make the following wiring connections Polaris EOS Jandy Zodiac Aqualink Aqualink TRi Green wire 0V to 0V termi...

Страница 17: ...ng Connections To verify the connection 1 Switch the MagnaPool Control Centre on and check the controller setting follow instructions under SETTING CONTROLLER 2 Re test the connection Note For safety...

Страница 18: ...r on the screen Note Low or Winter mode cannot be selected when controlled by an external controller Automatic Setting The MagnaPool system can be connected to the valves of an automatic pool spa syst...

Страница 19: ...run at 100 for a cumulative total of 24 hours before reverting to the previous output setting NOTE The BOOST mode cannot be engaged under the following circumstances 1 If in the OFF operating mode Th...

Страница 20: ...DIAG menu 3 Press to enter the HELP DIAG menu 4 Once in the HELP DIAG menu use the buttons to scroll to the error warning that has been displayed 5 Press A number of suggested solutions are momentaril...

Страница 21: ...sing the terminals 3 We recommend using Zodiac Salt Chlorinator Cell Cleaner to clean the electrode However you can mix your own by carefully adding one 1 part of Hydrochloric Muriatic acid to ten 10...

Страница 22: ...ld water Always maintain minerals at suitable levels If the light should activate and the water temperature is at swimming temperature it is recommended to add a bag of MagnaPool Minerals to the water...

Страница 23: ...21 Troubleshooting Additional information about this product can be found at magnapool com au For further information and assistance please consult your local pool professional Your Local Dealer...

Страница 24: ...of the Product or the payment of the cost of having the Product repaired or replaced 3 This express warranty does not apply in the following circumstances a if the Product has not been installed in ac...

Страница 25: ...rs are subject to the following pro rata pricing procedure The Purchaser must pay for the replacement electrode a proportion of the cost equal to that proportion of the warranty period during which th...

Страница 26: ...ion to each warranty claim whether the Product should be returned to the Authorised Dealer at the address where the Purchaser purchased the Product or whether warranty service will be provided in the...

Страница 27: ...le quality and the failure does not amount to a major failure Purchasers in other Countries 14 The laws and regulations of other countries may confer on Purchasers in those countries additional rights...

Страница 28: ...ustralia 219 Woodpark Rd Smithfield NSW 2164 Australia Tel 1800 688 552 Fax 1300 781 688 Email aftersales zodiac com au www zodiac com au Due to constant developments and improvements specifications m...

Отзывы: