![Zodiac Pool Systems JANDY TRUCLEAR XL Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/zodiac-pool-systems/jandy-truclear-xl/jandy-truclear-xl_installation-and-operation-manual_936590010.webp)
WARNING
To minimize risk of severe injury or death, filter, pump, and/or chlorinator should not be subjected to the
piping system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements
are generally not intended to apply to the pool equipment, such as filters, pumps, or chlorinators.
Jandy pool equipment is pressure tested at the factory.
If, however, the WARNING cannot be followed and pressure testing of the piping system must include the
filter, pump, and/or chlorinator,
BE SURE TO COMPLY WITH THE FOLLOWING SAFETY
INSTRUCTIONS:
Remove cell and install Pressurizing, Installation and Winterizing Cap (P/N: R0621900) before
testing.
Check all clamps, bolts, lids, lock rings, and system accessories to ensure they are properly
installed and secured before testing.
RELEASE ALL AIR in the system before testing. AIR PRESSURE must NOT be used for pressure
testing.
Water pressure for test must NOT EXCEED 35 PSI.
Water temperature for test must NOT EXCEED 38°C (100°F)
Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult the
equipment manufacturer.
SAVE THESE INSTRUCTIONS