Fill Will Not Turn ON
Disconnect orange
sensor wires at
control box.
Is power
light on?
Disconnect blue valve
wires from control box.
Does
green fill light
turn on?
Does
green fill light
turn on?
Wait 20 seconds.
Does sensor
light turn on?
Transformer
is bad.
Turn on
power.
Sensor is bad.
Check blue wires with AC
voltmeter. Is there 24 VAC?
Check for power at valve
connection. Is there power?
PBC board is bad.
Valve is bad.
Cable connection between
valve and controller is bad.
Less power.
Verify correct input
voltage to unit.
Pull sensor out of water.
Does sensor
light turn on?
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
Does unit have power?
No power.
Lockout sequence
has taken effect.
Call technical support
(707) 776-8200
ext 260.
Is fill
light red?
NO
YES
YES
NO
5.5 Fill Will Not Turn ON
This is a troubleshooting flow chart for models K-1100, LX2, and LEV110CK/2G. Use it when the Fill function will
not turn on.
Page 21
ENGLISH
Jandy Pro Series Levolor
®
Electronic Water Leveler
Models K-1100, LX2, K-2300, and LEV110CK/2G
|
Installation and Operation Manual