6. The
Jandy™
AquaLink™
RS or PDA and power pack
use a four (4) wire connection to communicate and can be
wired up to 152.4 m (500 ft) apart. Any outdoor rated four conductor cable, minimum 0.33 mm
2
(22 AWG), can
be used. Locate the appropriate screw terminals on the circuit board and wire the power pack
to the AquaLink
RS
or PDA red 4-pin terminal bar (see Figure 26).
NOTE
The screw terminals on the AquaLink RS or PDA are removable to aid in installation.
3.7.3 Testing
the
Connection
Once the power pack has been wired to the AquaLink RS Control System or PDA, follow these steps to test the
connection:
1.
Apply power to the power pack and the AquaLink RS Control System or PDA.
2.
Wait about 20 seconds. If the connection was successful, a
Ŧ
symbol will appear in the top right corner of the
power pack display.
NOTE:
If the power pack does not connect to the controller, turn the power off to both devices and repeat steps 1 and 2. If
the power pack still does not connect to the controller, re-check the wiring connections (see Section 3.7.2) and the
controller setting on the power pack (see Section 3.7.1).