Driver Installation 

This section covers driver installation for the NetBlaster adapter. At this stage the adapter should 
be secure in the system and all Ethernet cables should be attached. If this is not the case, return 

to the “Hardware Installation” procedure in the previous section.  

 

Download the specific driver for your system from the ZNYX web site (

www.znyx.com

). 

Included on the web site with the driver are release notes with installation and configuration 

instructions. Follow the directions on line to configure the driver.

 

Running DOS Diagnostics 

DOS-based diagnostics are also available from the ZNYX web site (

www.znyx.com

) to help 

troubleshoot hardware problems. If you believe you have a hardware problem, and have the 

capability to run DOS-based diagnostics, the steps below outline the use of the diagnostics.  

Testing ZX478 Adapters in DOS 

1.  Run the diagnostic program to see if your adapter has been properly configured. Run 

DIAG478.EXE off your diskette by entering: 

 

>DIAG478 LIST

 

2.  You will see a list below. (This example is for the ZX478.) 

 

 

DIAG478 Version 2.04 for ZNYX NetBlaster ZX478

8/100 Mbps adapter

(c) Copyright 1994-1999 ZNYX Corporation - All Rights Reserved.
PCI BIOS Information: Version=2.10, Config Mechanism=1, Last Bus=2

Bus Dev Fn

Vendor Device Rev

Type

Lat IL IRQ

Note

==========

=================

============

==========

=====

0

0

0

8086

1250

03

Host Bridge

20

-

-

0

7

0

8086

7000

01

PCI-ISA

00

-

-

0

7

1

8086

7010

00

IDE

20

-

-

2

12

0

1011

0046

01

Ethernet

73

A

10

ZX478

2

412

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

512

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

612

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

712

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

812

0

1011

0019

41

Ethernet

73

A

10

ZX478

2

912

0

1011

0019

41

Ethernet

73

A

10

ZX478

2 1012

0

1011

0019

41

Ethernet

73

A

10

ZX478

2 1112

0

1011

0019

41

Ethernet

73

A

10

ZX478

1

0

0

8086

7800

21

VGA

0

A

5

 

 

3.  You should see nine Ethernet-type devices (one the bridge, and one for each of the eight 

ports), and the “Note” column should indicate the device to be a ZX478. Each should have 

an 

IRQ

 (interrupt line), 

bus

 value, and a unique 

device

 number. If so, your card has been 

automatically configured. Make a note of the 

bus

 and 

device 

numbers and go on to the 

software installation section. 

 

Содержание NetBlaster ZX470 Series

Страница 1: ...NetBlaster ZX470 Series User s Guide Fast Ethernet Adapters with Hot Swap and Rear I O for Compact PCI Systems...

Страница 2: ...tice ZNYX RAIN RAINlink and NetBlaster are trademarks or registered trademarks of ZNYX Corporation in the United States and or other countries All other marks trademarks or service marks are the prope...

Страница 3: ...ub connector MDI X with Type AB interconnect 6U ZX408H Eight channel rear transition module hub connector MDI X 6U ZX408HAB Eight channel rear transition module hub connector MDI X with Type AB interc...

Страница 4: ...may vary depending on the specific system used Refer to the system s documentation if necessary The figure below shows the installation of an adapter in a typical system ZX478 CPCI Adapter ZX408 Rear...

Страница 5: ...t must be properly aligned and the adapter fully seated A good seat is achieved when the bracket touches the system case up to the extraction levers Rear transition modules are available with Type B o...

Страница 6: ...r diskette by entering DIAG478 LIST 2 You will see a list below This example is for the ZX478 DIAG478 Version 2 04 for ZNYX NetBlaster ZX478 8 100 Mbps adapter c Copyright 1994 1999 ZNYX Corporation A...

Страница 7: ...the device numbers are 412 and 512 run DIAG478 2 412 DIAG478 2 512 5 If the DIAG478 program says Running diagnostics for ZX478 channel at Bus 2 Device 412 Configuration I O 400E800 IRQ 10 Node 00C095C...

Страница 8: ...dicating continuity with the Rear Transition Module The front panel also includes the industry standard blue LED next to the bottom Hot Swap ejector tab The LED s are defined by the following table La...

Страница 9: ...assistance after referring to this User s Guide ZNYX has a professional technical support team available to answer your questions Contact us at Telephone 510 249 0800 or 800 724 0911 Fax 510 646 2460...

Страница 10: ...ay cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the i...

Страница 11: ...ZNYX or an authorized dealer Should this product in ZNYX s opinion malfunction during the applicable warranty period ZNYX will at its expense repair the defective product or part or at its option del...

Отзывы: