ZNYX NetBlaster ZX470 Series Скачать руководство пользователя страница 3

 

ZNYX

 NetBlaster 470 Series cPCI Fast Ethernet Adapter 

User’s Guide  

 

 

Page 3

 

Thank you for choosing the ZNYX NetBlaster 470 Series CompactPCI (cPCI) Fast Ethernet 

Adapter. The NetBlaster 470 series is a fully featured product family of carrier Class 

CompactPCI Fast Ethernet adapters for high availability applications requiring state-of-the-art 

LAN interfaces. The 470 series features:  
 

• 

Four or Eight channel configurations, 6U form-factor 

• 

Rear I/O via passive 6U x 80mm rear transition module 

• 

Hot swap capability 

• 

64-bit data bus 

• 

Designed for NEBS Level 3 systems 

 

Your adapter is designed to provide a lifetime of superior service in your system with cPCI slots.  

NetBlaster ZX470 Series Fast Ethernet Adapter Models 
 

Model 

Fast Ethernet Channels 

cPCI Slot 

ZX474 

Four 10/100 Mbps 

6U 

ZX478 Eight 

10/100 

Mbps 

6U 

ZX404H 

Four-channel rear transition module hub 
connector (MDI-X) 

6U 

ZX404HAB 

Four-channel rear transition module hub 
connector (MDI-X) with Type-AB interconnect 

6U 

ZX408H 

Eight-channel rear transition module hub 
connector (MDI-X) 

6U 

ZX408HAB 

Eight-channel rear transition module hub 
connector (MDI-X) with Type-AB interconnect 

6U 

ZX404A 

Four-channel rear transition module adapter 
connector (MDI) 

6U 

ZX404AAB 

Four-channel rear transition module adapter 
connector (MDI) with Type-AB interconnect 

6U 

ZX408A 

Eight-channel rear transition module adapter 
connector (MDI) 

6U 

ZX408AAB 

Eight-channel rear transition module adapter 
connector (MDI) with Type-AB interconnect 

6U 

Documentation and Software 

Documentation and software for the NetBlaster adapter is distributed electronically. You can 

retrieve most recent drivers and documentation and drivers from the ZNYX web site, 

www.znyx.com

 in the driver download section. Please contact ZNYX Customer Support at (800) 

724-0911 if you have trouble locating the appropriate driver or installation documentation. 

Installation Procedure 

There are two basic steps you need to follow to operate the NetBlaster adapter.  

 

1.  Install the hardware (NetBlaster adapter and rear transition card). 
2.  Install the driver. 

Содержание NetBlaster ZX470 Series

Страница 1: ...NetBlaster ZX470 Series User s Guide Fast Ethernet Adapters with Hot Swap and Rear I O for Compact PCI Systems...

Страница 2: ...tice ZNYX RAIN RAINlink and NetBlaster are trademarks or registered trademarks of ZNYX Corporation in the United States and or other countries All other marks trademarks or service marks are the prope...

Страница 3: ...ub connector MDI X with Type AB interconnect 6U ZX408H Eight channel rear transition module hub connector MDI X 6U ZX408HAB Eight channel rear transition module hub connector MDI X with Type AB interc...

Страница 4: ...may vary depending on the specific system used Refer to the system s documentation if necessary The figure below shows the installation of an adapter in a typical system ZX478 CPCI Adapter ZX408 Rear...

Страница 5: ...t must be properly aligned and the adapter fully seated A good seat is achieved when the bracket touches the system case up to the extraction levers Rear transition modules are available with Type B o...

Страница 6: ...r diskette by entering DIAG478 LIST 2 You will see a list below This example is for the ZX478 DIAG478 Version 2 04 for ZNYX NetBlaster ZX478 8 100 Mbps adapter c Copyright 1994 1999 ZNYX Corporation A...

Страница 7: ...the device numbers are 412 and 512 run DIAG478 2 412 DIAG478 2 512 5 If the DIAG478 program says Running diagnostics for ZX478 channel at Bus 2 Device 412 Configuration I O 400E800 IRQ 10 Node 00C095C...

Страница 8: ...dicating continuity with the Rear Transition Module The front panel also includes the industry standard blue LED next to the bottom Hot Swap ejector tab The LED s are defined by the following table La...

Страница 9: ...assistance after referring to this User s Guide ZNYX has a professional technical support team available to answer your questions Contact us at Telephone 510 249 0800 or 800 724 0911 Fax 510 646 2460...

Страница 10: ...ay cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the i...

Страница 11: ...ZNYX or an authorized dealer Should this product in ZNYX s opinion malfunction during the applicable warranty period ZNYX will at its expense repair the defective product or part or at its option del...

Отзывы: