 NetBlaster ZX222 PMC Fast Ethernet Adapter · User’s Guide  

Page 4

 

Hardware Installation 

Below are the steps necessary to install a NetBlaster adapter into a standard, PMC compliant 

system. The following are detailed instructions for the hardware installation procedure. 

Installing the Hardware 

This installation procedure is for installing NetBlaster PMC adapter systems with an embedded 
PMC slot. Some steps in this procedure may vary depending on the specific system used. Refer 

to the system’s documentation if necessary. 
 
The figure on the following page shows the installation of an adapter in a typical system.  

 

 

Zx222 PMC Adapter

 

Observe proper Electro-Static Discharge prevention

 

procedures at all times. Failure to do so may result

 

in damage to the PCI Adapter or to the system.

 

!

 

!

 

Do not use excessive

 

force.

 

0  I

 

 

CPCI PMC Carrier Card

 

 

 
1. 

Turn off

 your system. 

 
2. 

Discharge any static electricity

 from your body by touching the metal chassis, or by using 

an anti-static wrist strap. If you do not have a ground strap, maintain physical contact with 
the case to maintain the same electrical potential with the system. 

 

3. 

Remove the motherboard or carrier card

 containing at least one available single-wide 

PMC slot. Select a slot to install the ZNYX Networks NetBlaster adapter. Remove the cover 

from the PMC slot. 

 

Содержание NetBlaster ZX222

Страница 1: ...NetBlaster ZX222 User s Guide Fast Ethernet Adapter for PCI Mezzanine Connector PMC...

Страница 2: ...works RAIN RAINlink and NetBlaster are trademarks or registered trademarks of ZNYX Networks in the United States and or other countries All other marks trademarks or service marks are the property of...

Страница 3: ...umentation and drivers from the ZNYX Networks web site in the driver download section Please contact ZNYX Networks Customer Support if you have trouble locating the appropriate driver or installation...

Страница 4: ...wing page shows the installation of an adapter in a typical system Zx222 PMC Adapter Observe proper Electro Static Discharge prevention procedures at all times Failure to do so may result in damage to...

Страница 5: ...switch with any standard SC multimode fiber cable Driver Installation This section covers driver installation for the NetBlaster adapter At this stage the adapter should be secure in the system and al...

Страница 6: ...d have an IRQ interrupt line bus value and a unique device number If so your card has been automatically configured Make a note of the bus and device numbers and go on to the software installation sec...

Страница 7: ...ating system specific documentation to evaluate any error messages or logs when the driver is loaded Technical Support If you need further assistance after referring to this User s Guide ZNYX Networks...

Страница 8: ...to cause harmful interference in which case the user will be required to correct the interference at his own expense Canada Compliance This Class A digital apparatus complies with Canadian ICES 003 Ce...

Страница 9: ...product that it is to be in good working order for a period of twelve 12 months from the date of purchase from ZNYX Networks or an authorized dealer Should this product in ZNYX Network s opinion malf...

Отзывы: