the limit of free space available on a default system, so you may need to clear some space
prior to downloading the new OpenArchitect image to the switch.
CAUTION: Do not remove the existing copy of
/usr/sbin/gated
(as suggested
in Step 5, below) until you have, in fact, determined that an OpenArchitect upgrade
version is available for downloading.
5.
One of the easiest ways to create free space is to remove
/usr/sbin/gated
, as the
application will be replaced during the update procedure. Once you have enough free
space, proceed.
6. From the switch console,
ftp
the new OpenArchitect (rdr) image from the local system
to your switch.
7. The switch has two flash available: Device 1 and device 2. Use the
zflash
command to
write the new OpenArchitect image into the first flash device.
IMPORTANT: Make sure that Surviving Partner is not running before using
zflash
. The
delays incurred while
zflash
writes the flash can cause the Surviving Partner daemons to
think there is a failure, resulting in link oscillation.
zflash -d 1 <image_file>
The image file will be something named similar to the following,
zflash -d 1 rdr6000.zImage.initrd
Upgrading or Adding Files
Follow the procedure below to upgrade or add a new file to the switch. Place the file you are
adding or upgrading into the appropriate location in the file system. Save the file in the overlay
directory area on the application flash by running
zsync
.
zsync
After running
zsync
, the file is saved to the flash for future reboots.
Excluding Saving Files to Flash
Specific files or directories can be excluded from saving to flash by
zsync
by including an entry
in
/etc/exclude
. Likewise, existing entries in
/etc/exclude
such as
/tmp
can be removed
in order to save those files to flash with
zsync
.
Upgrading the Switch Driver
The switch driver upgrade process is the same as a file upgrade. However, more caution should
be taken since the driver module is likely to be the method by which you are logging into the
system. If the switch driver has a problem, you will need to have a console cable to recover. To
upgrade a switch driver, replace the file
/lib/modules/if_zxe.o
, run
zsync
and reboot.
Ethernet Switch Blade User's Guide
release 3.2.2j
page 143
Содержание bh5700
Страница 2: ...Ethernet Switch Blade User s Guide release 3 2 2j page ii...
Страница 15: ...Ethernet Switch Blade User s Guide release 3 2 2j page 15...
Страница 16: ...Ethernet Switch Blade User s Guide release 3 2 2j page 16...
Страница 25: ...Ethernet Switch Blade User s Guide release 3 2 2j page 25 Figure 2 1 LED Reference...
Страница 26: ...Ethernet Switch Blade User s Guide release 3 2 2j page 26...
Страница 227: ...SEE ALSO ifconfig 8 Ethernet Switch Blade User s Guide release 3 2 2j page 227...
Страница 237: ...be also reset SEE ALSO zspconfig Ethernet Switch Blade User s Guide release 3 2 2j page 237...
Страница 239: ...SEE ALSO ztmd tc 8 zfilterd Ethernet Switch Blade User s Guide release 3 2 2j page 239...
Страница 262: ...SEE ALSO zqosd iptables 8 tc 8 zfilterd Ethernet Switch Blade User s Guide release 3 2 2j page 262...
Страница 265: ...SEE ALSO zconfig zl2d Ethernet Switch Blade User s Guide release 3 2 2j page 265...
Страница 318: ...be also reset SEE ALSO zspconfig Ethernet Switch Blade User s Guide release 3 2 2j page 318...
Страница 320: ...SEE ALSO ztmd tc 8 zfilterd Ethernet Switch Blade User s Guide release 3 2 2j page 320...
Страница 335: ...Ethernet Switch Blade User s Guide release 3 2 2j page 335...
Страница 344: ...SEE ALSO zqosd iptables 8 tc 8 zfilterd Ethernet Switch Blade User s Guide release 3 2 2j page 344...
Страница 359: ...Index ztmd 301 zvlan 179 258 ZX4920 MIB 333 7100 User s Guide release 3 2 2j page 359...