background image

P a g e  

8 | 14

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Use a torque wrench for installation, and the compression for each clamps is not strong to avoid potential 
damages to module frames. The recommended maximum compression for each clamp is 20MPa (2900PSI). 

 

The module mounting structure must be made of durable, corrosion-resistant and UV-resistant material. All 
mounting hardware (bolt/flat washer/split washer/nut) should be stainless steel M8 size. 

 

The minimum recommended length for each clamp is 60mm. 

 

The modules have been designed to resist a static load, and the resistance value can decrease if modules are 
not mounted following the instruction above. 

 

This manual is just for reference. Customer can  select the corresponding installation manual based on the 
purchased module.

 

 
7

Wiring   

● 

The modules use thePV-JX1203    type junction box. This box, on the back side of the module, is 

weatherproof and is designed to be used with standard wiring or conduit connections. Wiring methods 

should be in accordance with the NEC (National Electrical Code). Bypass diodes and cable clamps are 

included with each module when shipped from the factory.   

● 

Correct wiring scheme   

When designing the system, avoid forming loops to minimize risk in the event of an indirect lighting 

strike. Check that wiring is correct before starting the generator. If the measured open circuit voltage 

( Voc) and short-circuit current (Isc) differ from the specifications, then there is a wiring fault.   

● 

Correct connection of contact plug connectors   

Содержание ZXM6-H144

Страница 1: ...ration and maintenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and mainte...

Страница 2: ...H120 ZXP6 H120 Max series fuse rating A 15 Nominal Mass 22 5kg 21 5kg 21kg 20 5kg 20 5kg 19 5kg Package Size mm 2000x992x40 35 2024x1002x40 35 2020x1002x40 35 2040x1002x40 35 1844x992x40 35 1860x1002...

Страница 3: ...ces If there is exposure to salt i e marine environment and sulfur i e sulfur sources volcanoes there is a risk of corrosion It s not recommended to install the modules when the distance is less than...

Страница 4: ...ns where the solar modules are mounted to a permanent structure the solar modules should be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will...

Страница 5: ...he bolt and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or...

Страница 6: ...secure the modules to support structure Always use all the eight mounting holes to secure the modules The module installed with screws on the front frame for load see the following picture and refer...

Страница 7: ...can run off freely to avoid standing water or pudding This resistance value can decrease if modules are not mounted following the instructions above B Clamping installation Only for frame with 40mm t...

Страница 8: ...just for reference Customer can select the corresponding installation manual based on the purchased module 7 Wiring The modules use thePV JX1203 type junction box This box on the back side of the modu...

Страница 9: ...oose the control box with LJQ 1 LJQ 3 type Connectors 8 Maintenance and cleaning Do not change the PV components optionally diode junction box plug connectors Given a sufficient tilt at least 15 it is...

Страница 10: ...iring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concentrated sunlight shall not be directed on the modules or panels 11 Danger of death from arc...

Страница 11: ...anels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8 5 3 4 1 2 PV modules were manufactured by ZNshine ZNSHINE PV TECH Co Ltd No 1 South Zhenxing Road Industrial Zone Z...

Страница 12: ...Power Pm W 390 395 400 405 Max Power Voltage Vmp V 40 6 40 8 41 41 2 Max Power Current Imp A 9 61 9 69 9 76 9 84 Open Circuit Voltage Voc V 48 7 48 9 49 1 49 3 Short Circuit Current Isc A 10 08 10 16...

Страница 13: ...s Fuse A 15 Electrical Performance STC Model Type ZXM6 H120 315 M ZXM6 H120 330 M Max Power Pm W 315 330 Max Power Voltage Vmp V 33 2 33 8 Max Power Current Imp A 9 49 9 77 Open Circuit Voltage Voc V...

Страница 14: ...dule mm kg Dimensions mm Weight kg 1675x992x40 35 VDC Max System Voltage VDC 1500 A Max Series Fuse A 15 Electrical Performance STC Model Type ZXP6 H120 300 P Max Power Pm W 300 Max Power Voltage Vmp...

Отзывы: