ZMC308E Motion Controller Hardware Manual V1.5
the shielding layer is fully grounded.
⚫
On-site wiring should also pay attention to the distance between strong current and
weak current wiring, it is recommended to be more than 20cm.
⚫
It should be noted that the equipment grounding (chassis) on the entire line must be
good, and the grounding of the chassis should be connected to the standard factory
ground pile.
→
Cable Requirements:
Twisted pair shielded wire, and shielded cable grounded.
3.2.2.
Basic Usage Method
(1)
Please follow the above wiring instructions for correct wiring.
(2)
After power on, please use ETHERNET or RS232 or RS485 to connect to ZDevelop.
(3)
Please use the "ADDRESS" and "SETCOM" commands to set and view the protocol
station number and configuration parameters, see "ZBasic Programming Manual" for
details.
(4)
Please use the "CANIO_ADDRESS" command to set the master's "address" and
"speed" according to the needs, and use the "CANIO_ENABLE" command to enable or
disable the internal CAN master function, or through "ZDevelop/Controller/State the
Controller/Communication
Info” to
view the CAN status intuitively, and refer to the
“ZBasic Programming Manual” for details
.