XPLC3264E Controller Manual
15
7
OUT12
Output 12
8
OUT13
Output 13
9
OUT14
Output 14
10
OUT15
Output 15
Please separate the internal power supply 24V and external IO power supply 24V,
especially in the case of severe electromagnetic interference on site.
2.2.6
Output 3-4 / axis pulse signal
Pin
number
name
Explanation
Other
function
s
1
EGND
IO power ground
2
E5V
5V power generated
by IO power
Source, output,
<300MA.
3
OUT16
Output 16
DIR7
4
OUT17
Output 17
PUL7
5
OUT18
Output 18
DIR6
6
OUT19
Output 19
PUL6
7
OUT20
Output 20
DIR5
8
OUT21
Output 21
PUL5
9
OUT22
Output 22
DIR4
10
OUT23
Output 23
PUL4
Output 4 terminals:
Pin
number
name
Explanation
Other
function
s
1
EGND
IO power ground
2
E5V
5V power generated
by IO power
Source, output,
<300MA.
3
OUT24
Output 24
DIR3
4
OUT25
Output 25
PUL3
5
OUT26
Output 26
DIR2
6
OUT27
Output 27
PUL2
7
OUT28
500MA high current
output 28
DIR1
8
OUT29
500MA high current
PUL1
Содержание XPLC3264E