background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPLC3264E Controller Hardware 
Manual 

 

Version 1.1 

Содержание XPLC3264E

Страница 1: ...XPLC3264E Controller Hardware Manual Version 1 1...

Страница 2: ...manual Refer to the ZBASIC software manual for detailed information about the ZMC controller software and the introduction and routines of each instruction The information in this manual is for refer...

Страница 3: ...ller Manual 2 machine Please be sure to design an effective safety protection device in the machine and add an error handling program to the software otherwise the loss caused by the company is not ob...

Страница 4: ...wer CAN Interface signal 5 2 2 2 RS232 Interface signal 5 2 2 3 RS485 Interface signal 6 2 2 4 General input signal 6 2 2 4 1 Input 0 7 6 2 2 4 2 Input 8 15 7 2 2 4 3 Input 16 23 7 2 2 4 4 Input 24 31...

Страница 5: ...rts multi task running at the same time at the same time it can be directly simulated on the PC XPLC is a product of ZMC motion controller integrated ladder diagram and configuration software 1 1 Conn...

Страница 6: ...VB VS C Builder C and other software When debugging you can connect ZDevelop software to the controller at the same time and the dynamic library zmotion dll is needed when the program runs XPLC progra...

Страница 7: ...by CAN bus Can be expanded up to 512 isolated input or output ports Axis positive negative limit signal port origin signal port can be configured as any input port at will The maximum output current...

Страница 8: ......

Страница 9: ...PLC1664E XPLC2464E XPLC3264E Number of basic axes 16 twenty four 32 Maximum number of axes 32 32 32 Basic axis type EtherCAT pulse axis total 16 2 encoder shafts EtherCAT pulse axis total 24 2 encoder...

Страница 10: ...yte Flash space 128MByte 1000 blocks 128MByte 1000 blocks 8MByte 128 blocks power input 24V DC input IO24V output Into 24V DC input IO24V output Into 24V DC input IO24V output Into Communication Inter...

Страница 11: ...XPLC3264E comes with 32 general purpose input ports and 32 general purpose output ports common for pulse and output Common for encoder and input XPLC3264E has one RS232 serial port one RS485 one netwo...

Страница 12: ...XPLC3264E Controller Manual 6 0 10V...

Страница 13: ...isolated 24V outputs when the touch screen is connected through a serial port the power supply of the touch screen is provided by the internal power supply 24V For communication quality please use twi...

Страница 14: ...XPLC3264E Controller Manual 8 Pin number name Explanation 2 RXD Receive data pin 3 TXD Send data pin 5 GND Power ground 9 DC5V 5V power supply output can be used to power the text screen...

Страница 15: ...from here Electricity 2 2 3 RS485 interface signal Pin number name Explanation 1 A Differential data 2 B Differential data 3 GND Power ground 2 2 4 General input signal 2 2 4 1 Enter 0 7 Pin number n...

Страница 16: ...XPLC3264E Controller Manual 10 Input 0 and input 1 have the function of latching input A and latching input B at the same time...

Страница 17: ...ut 1 have the function of latching input A and latching input B at the same time 2 2 4 3 Enter 16 23 Pin number name Explanation 1 EGND IO power ground 2 EGND IO power ground 3 IN16 Enter 16 4 IN17 En...

Страница 18: ...XPLC3264E Controller Manual 12 ground 2 EGND IO power ground 3 IN24 Enter 24 4 IN25 Enter 25 5 IN26 Enter 26 EZ1...

Страница 19: ...1 2 IO power signal Output circuit Pin number name Explanation 1 EGND IO power ground 2 E24V IO power supply 24V 3 OUT0 Output 0 4 OUT1 Output 1 5 OUT2 Output 2 6 OUT3 Output 3 7 OUT4 Output 4 8 OUT5...

Страница 20: ...XPLC3264E Controller Manual 14 6 OUT11 Output 11...

Страница 21: ...d 2 E5V 5V power generated by IO power Source output 300MA 3 OUT16 Output 16 DIR7 4 OUT17 Output 17 PUL7 5 OUT18 Output 18 DIR6 6 OUT19 Output 19 PUL6 7 OUT20 Output 20 DIR5 8 OUT21 Output 21 PUL5 9 O...

Страница 22: ...high current output 31 PUL0 The pulse port can use E5V common anode output or E24V common anode output Configure virtual axis for the corresponding axis When atype 0 it is a common output port otherwi...

Страница 23: ...The ordinary output port is used as a pulse port so it is an external power supply Some drives are For 24V interface OPTO can be directly connected to 24V Single ended connection Single ended wiring r...

Страница 24: ...IN1 0 10V analog input 1 XPLC3264E internal ADDA uses internal power supply third chapter Expansion module Please refer to ZIO Expansion Card Hardware Manual 3 1 Expansion moduleCAN bus input and outp...

Страница 25: ...XPLC3264E Controller Manual 19 CANH at the end...

Страница 26: ...whether the set deceleration and speed exceed the equipment limit Check whether the output pulse frequency exceeds the receiving limit of the driver Check whether the controller and the driver are pro...

Страница 27: ...input Check whether the IO power supply is available Check whether the signal level matches the input port Check if the input port number matches the ID of the IO board No response during output oper...

Страница 28: ...XPLC3264E Controller Manual 22 chapter Five Hardware installation Unit mm mounting hole diameter 4 5mm total height of the controller 45mm...