Problem
Suggestions
Motor does not rotate.
Check whether the ATYPE of the controller is
correct
Check whether the pulse input mode
matches the input pulse mode of the drive
Check whether the motor already reached
hardware or software position limit, resulting
in ALM signal comes
Check if pulse count is normal in ZDEVELOP.
The controller is working
normally, pulses is sent
out normally, motor still
does not rotate.
Check whether connection between drive
and motor is correct and whether connection
between the drive and the controller is
correct.
Check whether the drive works properly and
there is no alarm.
Motor can rotate, but it is
not working normally.
Check whether deceleration and speed
exceed the device limit
Check whether pulse frequency output
exceed the
receiving limit of the drive
Check
whether
connection
between
controller and drive are correct and whether
anti-interference measures are well done
Check whether current limiting resistance
used in the photoelectric isolation circuit of
pulse and direction signal output is too large
and the working current is too small.