Default functions mapping
F0
- Directionally controlled LV and LR outputs
F4
- AUX4 output
F1
- AUX1 output
F5
- Low beam light
F2
- AUX2 output
F6
- Shunting mode
F3
- AUX3 output
All functions and outputs can be reassigned using advanced function mapping
capabilities of the digital decoder. Please see complete Doehler & Haass®
programming manual for reference.
CV13-CV14 settings define which functions should be switched on in DC
analog mode. By default, F0 and F1 are active in analog mode.
CV
Description
Range Default
51 Swapping connections
Bit Function Value
0......Motor (swapping M1 and M2 outputs).....1
1......Light (swapping LV and LR outputs).........2
2......Track (swapping G1 and G2 outputs)........4
0-7
0
52 Dimming LV/LR outputs
0 = dark ... 31 = full brightness
0-31
31
53 Dimming low beam light
0 = dark ... 31 = full brightness
0-31
15
54 Dimming AUX1
0 = dark ... 31 = full brightness
0-31
31
55 Dimming AUX2
0 = dark ... 31 = full brightness
0-31
31
61 Maximum speed in shunting mode
0-127
63
62 Deceleration time in shunting mode
The value corresponds to the time in seconds
from the maximum shunting speed to stop
0-255
1
137 Advanced decoder settings
Bit Function Value
1......Switch off energy saving mode......2
0-63
0