p. 23/69
o
Connect the inflow and outflow of the hot water boiler to the heating
system – use appropriate fittings, etc, according to the installation project;
Figure 4.6 Backside view of the hot water boiler of series “Pyrotherm” -
the connections are pointed;
•
Position the boiler, considering the requirements for attaching the electrical
power supply – position the boiler in order to ensure easy access to the
power supply plug box (230V/50Hz);
ATTENTION: the finalization of the boiler’s installation and commissioning of
the boiler’s operation, as well as the heating systems, should be notified in the
warranty list – filling all the data fields is obligatory.
•
The heating system and the boiler should be filled up with circulating water –
most commonly tap water is utilized. However, the water, used for filling the
heating system should be transparent, colorless, no sediments, oil contents or
any other aggressive chemical components. The hardness as well as other
properties of the water should cover the requirements, described in the table
below. In case the water does not cover these requirements, it should not in
any case being used, the water should be chemically treated or other water
should be used instead.
Circulating water outflow (to
the heating system)
Circulating water inflow
(from the heating system)
Flue gases exit (to the
chimney)
Drainage orifice
Combustion air control flap