Thank you for buying a ZM–MAXXI hydraulic pump.
ZM–MAXXI pumps are designed to give you long service life,
low maintenance and constant water delivery.
First, some basic technical facts concerning installation and use.
Installation
Pumps should be installed on a level, firm platform or other concrete or wood surface. Set the pump frame level and
square on the platform, secure with bolts.
Then, assemble the pump, fitting the suction and propulsion pipes and the water wheel. Then bring a water stream to the
wheel (as shown) to commence operation.
Movement of the Wheel
The wheel can be driven by water falling from the open end of a wooden, cement, plastic or P.V.C. pipe.
Table of water flow need to move the wheel
MODEL
WATER FLOW TO
TURN WHEEL
ESTIMATED
FLOW
FLOW (l/sec)
DISTANCE
TOTAL HEAD
PRODUCTION
(l/day)
HEIGHT
FROM BASE
ZM 44 MAXXI
50mm – 100mm
50mm
2
12km
190m
4–10,000
1,5m
ZM 38 MAXXI
100mm – 150mm
50–75mm
2–4
12km
300m
5–11,000
1,75m
ZM 51 MAXXI
75mm – 200mm
75–200mm
4–30
12km
200m
9–18,000
1,9m
ZM 63 MAXXI
150mm – 200mm
200mm
15–30
12km
150m
16–32,000
2,0m
ZM 76 MAXXI
175mm – 250mm
250mm
30–60
12km
200m
30–55,000
2,3m
ZM 95 MAXXI
200mm – 300mm
300mm
50–70
12km
130m
40–90,000
2,5m
NB! For applications where water is to be lifted to heights greater than 70 meters between the pump and and the retention tank, an
additional wheel should be employed. This pump should also be driven by a more powerful water stream.
** Rotation estimated between 20 and 40 r.p.m. (revolutions/min)
A
Diameter of the wheel
B
Distance between the tube
and the top of the wheel:
approximately 10cm
C
Length of the tube:
D
Slope of the tube: 3% to 5%
of the length
E
Between the wheel and the
ground: not less than 10cm
A
Содержание ZM 44 MAXXI
Страница 1: ...Instruction Manual ZM Pompe...