General Precautions   

1.  Before using this Inverter, read all instructions and cautionary markings 

on : 

(1) Inverter      (2) the batteries    (3) this manual     

2.  CAUTION --To reduce risk of injury, charge only lead-acid rechargeable 

batteries. Other types of batteries may cause damage and injury. 

3.  Do not expose Inverter to rain, snow or liquids of any type. Inverter is 

designed for indoor. 

4.  Do not disassemble Inverter. Take it to a qualified service center when 

service or repair is required. 

5. 

WARNING:

 Provide ventilation to outdoors from the battery compartment. 

The battery enclosure should be designed to prevent accumulation and 

concentration of hydrogen gas at the top of the compartment. 

6. 

NEVER 

charge a frozen battery. 

7.  Input/output AC wiring must be no less than

 

18 AWG gauge copper wire 

and rated for 75

o

C or higher. Battery cables must be rated for 75

o

C or 

higher and should be no less than 10AWG gauge. The inner diameter of 

the copper ring terminal which is used to connect battery cables to 

Inverter DC terminals should be no less than 6mm. 

8.  Be extra cautious when working with metal tools around batteries. 

Short-circuiting the batteries could cause an explosion. 

9.  Read the battery manufacturer

s installation and maintenance instructions 

prior to operating. 

 

Personnel

 

Precautions 

1.  Have plenty of fresh water and soap nearby in case battery acid contacts 

skin, clothing, or eyes. 

2.  Avoid touching eyes while working near batteries. 

3.  NEVER smoke or allow a spark or flame in vicinity of a battery. 

4.  Remove personal metal items such as rings, bracelets, necklaces, and 

watches when working with batteries. Batteries can produce a short-circuit 

current high enough to make metal melt, and could cause severe burns. 

5.  If a remote or automatic generator start system is used, disable the 

automatic starting circuit or disconnect the generator to prevent accident 

during servicing. 

 

Содержание IG 1000-24-C

Страница 1: ...USER MANUAL...

Страница 2: ...ted for 75 o C or higher and should be no less than 10AWG gauge The inner diameter of the copper ring terminal which is used to connect battery cables to Inverter DC terminals should be no less than 6...

Страница 3: ...he battery set via charging system In UPS mode Inverter automatically convert battery energy into AC power for backing up the connected devices Features l Automatic line to battery switchover l Select...

Страница 4: ...eries are connected press this button and Inverter will turn on automatically and works in mains mode or inverter mode according to input AC source s status When press this button again Inverter will...

Страница 5: ...s below Remark Off mode charging is same 7 Load level definition the tolerance is 10 rating power When over load the mark will flicker every 1second status Battery voltage 12V 24V 1 2 3 4 CC CV Bat 13...

Страница 6: ...t status Overload 1 Vout 195V 0 Off Output voltage RMS low 2 Off Short circuit 3 Off Fan locked 4 On 4 Off Battery voltage high 5 On 5 Off Overload 2 Vout 195V Pout 80 rated half wave load 6 On 6 Off...

Страница 7: ...neral electrical appliance If you select this mode the Inverter operating voltage in Line mode is within 170 280Vac 90 145Vac with the same output voltage The line sensitivity is higher Hence you can...

Страница 8: ...ter reboot Battery Connection Step 1 Pinch the bottom of DC input cover and Open it See Figure 4 Step 2 Following battery polarity guide located near battery terminal Place the battery cable ring term...

Страница 9: ...ngly recommend that you should isolate the battery terminals before you start to operate the unit Please refer to below instruction for further information If you parallel more batteries to extend the...

Страница 10: ...4VDC l Parallel battery connection When using multiple batteries in parallel each battery s voltage must be equal to the voltage of Inverter Nominal Input Voltage see specs AC Connection Before having...

Страница 11: ...s and fault 29V 0 6V charger stops and fault TRANSFER TIME Typical 10 20ms typical narrow range 40ms max wide range EFFICIENCY AC to AC 95 DC to AC 80 INDICATOR AC Mode Green lighting Battery Mode Yel...

Отзывы: