background image

 

1. PRODUCT OVERVIEW 

This is a DC-to-AC inverter with integrated solar battery charger, which can 

be used as a long run-time UPS (Uninterruptible Power Supply), an energy-

saving  solution  or an automotive inverter  (hereinafter referred to as 

inverter

”). 

The inverter accepts input  power source  from AC mains (utility),  battery, 

and  PV  (solar)  string  and switches between various operation modes 

automatically depending on the operational conditions.  
When used as an UPS, battery or PV (solar) string act as back-up power 

source to supply loads during the outage of AC mains.  
When used as an energy-saving device, the PV (solar) string can be set as 

priority to supply the loads without consuming the power from AC mains, as 

long as sufficient sunlight is present.  
The battery can be charged by both AC mains and PV (solar) string with 

intelligent charging control. 
Key features: 

 

Automatic line-to-battery switchover 

 

Built-in enhanced AC charger 

 

Built-in solar charger controller up to 40A 

 

Selectable Input voltage ranges/AC charging current/ AC or solar charger 

priority 

 

High efficient DC-to-AC conversion with minimized energy loss 

 

Rack design & wall-mounted design for flexible installation 

 

Intelligent 3-stage charger control for efficient charging and preventing 

overcharge 

 

Auto restart upon AC recovery 

 

User-friendly LCD and LED indications 

 

Multiple protections: low battery alarm, low battery shutdown, over 

charger  protection, overload protection, over temperature protection, 

short circuit protection

 

 

 

Содержание HD Plus 1000VA

Страница 1: ...INSTALLATION AND OPERATION MANUAL HD Plus 1000VA 2000VA WITH SOLAR CHARGE CONTROLLER...

Страница 2: ...irect sunlight rainfall or snow Before performing any maintenance on the product please disconnect all power sources AC mains batteries solar panel to avoid the risk of electrical shock Do not attempt...

Страница 3: ...tion Acts of third parties atmospheric discharges excess voltage chemical influences natural wear and tear and for loss and damage in transit Improper testing operation maintenance adjustment repair o...

Страница 4: ...erter on the Wall 5 2 3 Batteries 6 2 4 PV solar string 8 2 5 Connect AC Input Cables and Loads 9 2 6 AC Input Voltage Range Selector 9 3 OPERATION 10 3 1 Standby Charging Mode 10 3 2 Operation Modes...

Страница 5: ...to supply the loads without consuming the power from AC mains as long as sufficient sunlight is present The battery can be charged by both AC mains and PV solar string with intelligent charging contro...

Страница 6: ...dicators Rear Panel Battery Input AC input fuse AC input receptacle AC output receptacle PV Input AC input voltage range selector refer to section 2 6 PV Utility priority choice switch refer to sectio...

Страница 7: ...old by the numeric reading This icon is showed when PV solar system presents Input voltage level can be told by the numeric reading This icon is showed total PV generating capacity Level of remaining...

Страница 8: ...nce every 2 second Line Mode battery is being charged and not full Blinks twice every 5 second Standby Charging Mode Yellow On Backup Mode Red On Fault event Blinks every 0 5 second Overloading 1 2 Ty...

Страница 9: ...on horizontal surface or be mounted on the wall with various ways as shown below When mounting the inverter on the wall 1 The wall shall be solid and strong enough to carry the inverter 2 The location...

Страница 10: ...e no less than 6 AWG with 105 C rating No matter how the batteries are connected in series or in parallel make sure the cables terminal voltage is consistent with the inverter s specification 12V for...

Страница 11: ...iple 12V batteries While the total capacity is times by the number of battery the terminal voltage remains 12V Charging Current Setting Switch available on 1000VA model only The user of 1000VA model m...

Страница 12: ...ground e g thin film panel Connect the PV strings As the PV string generates power as long as illumination exists a circuit breaker shall be installed between the PV string and inverter so that the p...

Страница 13: ...280VAC while output voltage follows input voltage B WIDE setting Set the selector to WIDE when connected with loads which are less sensitive on voltage range e g light bulb fan fluorescent tube or TV...

Страница 14: ...called Standby Charging Mode When AC input cable and battery is connected the inverter will enter into Standby Charging Mode and LCD will be turned on with the following display If PV string is also...

Страница 15: ...peration mode according to the condition of AC input and PV input as shown in the table below LINE MODE 1 AC input power is present but there is no PV power e g night time Load is supplied by AC input...

Страница 16: ...emed an energy saving operation BACKUP MODE 1 Both AC input and PV input are absent The backup power to load comes only from battery The backup time is determined by the capacity of battery BACKUP MOD...

Страница 17: ...arge the battery As long as the PV power persists the load can be powered continuously without consuming power from battery 3 3 Fault Mode Inverter enters into Fault Mode when there is a fault event T...

Страница 18: ...UP MODE OUTPUT Voltage 230VAC 10 18 Frequency 50Hz or 60Hz Auto detection Output Waveform Modified Sine wave EFFICIENCY 80 OVERLOAD PROTECTION 1min 110 20s 120 0s 150 PROTECTION Discharge over charged...

Страница 19: ...ion D x W x H 275mm 226mm 85mm Net Weight kg 2 50 2 47 ENVIRONMENT Operating Environment 0 50 C 5 90 relative humidity non condensing Storage Environment 15 C to 55 C 5 to 95 humidity non condensing N...

Страница 20: ...port the fault to service representative for further assistance Alarm Behavior Table Fault Description Line Mode Backup Mode Fault Code No of Beeps AC Output No of Beeps AC Output Overload 1 Vout 195V...

Страница 21: ...n connecting the above PV string in parallel the max voltage and current of the total string is Vtotal Vstring1 Vstring2 Vstring3 Vstring4 Itotal Istring1 Istring2 Istring3 Istring4 In either case the...

Страница 22: ...000VA model to PV panels with the following parameters Pmax 80W Voc 21 6V Isc 5 17A Vmp 17 2V Imp 4 65A 1 The max PV input power for 1000VA model is 450W 450W 80W 5 6 max 5 PV panels shall be connecte...

Страница 23: ...ange is 30 36V 36V 17 45V 2 1 max number of PV panel in series is 2 3 Max charging current is 40A 40A 7 01A 5 7 max number of PV panel in parallel is 5 4 Taking 1 3 into consideration the optimized co...

Страница 24: ...please contact the local dealer for disposal instructions The product must not be disposed of with the household waste Disposal of the product at the end of its service life shall be done in accordanc...

Отзывы: