12
Gas Connection
Manual Shut-Off Valve
This valve is not shipped with the appliance and must be provided by the installer.
The manual shut-off valve must be installed in the gas service line between the gas
hook-up on the wall and the appliance inlet, in position where it can be reached
quickly in the event of an emergency.
In Massachusetts:
A T handle type manual gas shut-off valve must be installed in the
gas supply line to this appliance.
Flexible Connections
In case of installation with flexible couplings and/or quick-disconnect fittings, the
installer must use a heavy duty, AGA design-certified commercial flexible connector
of at least ½˝ (1.3cm) IF NPT (with a suitable strain relief in compliance with ANSI
Z21.41 and Z21.69 standards.
In Massachusetts:
The unit must be installed with a 36˝ (3 foot long) flexible gas
connector.
In Canada:
Use CAN 1-6. 10-88 metal connectors for gas appliances and CAN
1-6.9 M79 quick disconnect device for use with gas fuel.
Pressure Test Point Stopper Valve
To avoid gas leaks, the pressure test-point stopper valve and gasket supplied with the
range must be installed on the gas fitting at the back of the range according to the
diagram below.
Gas pipe
Gasket
Gas connection adaptor 1/2” NPT with
pressure test point 1/8” NPT (to be fixed
toward external side of the appliance)
Pressure test-point stopper
Содержание RTB30
Страница 1: ...Rangetops Installation Guide and Users Manual...
Страница 28: ...19 Users Manual...