U2000 Standalone Terminal connect with parking barrier
8. Note
The Standalone Terminal cannot be installed in a high-voltage environment, for example,
high tension wires and high-voltage transformers.
The Standalone Terminal cannot be installed near strong magnetic field.
If the Standalone Terminal is installed at a T-junction or a 90° corner or in other unfavorable
environment, the Standalone Terminal may fail to read the card due to the overlarge reading
angle. You can install an additional Standalone Terminal at the corner to solve the problem.
For such terrains as slopes, adjust where the Standalone Terminal faces, turning it downwards
within the effective range of card reading.
Remote card reading by the UHF Standalone Terminal is affected by the protective film
(explosion-proof film) on car windows to some extent.
Remote card reading by the UHF Standalone Terminal is affected on rainy, snowy or windy
days to some extent.