ZKTeco TS3000 Series Скачать руководство пользователя страница 3

 

 

 
2.

 

Rotating the arms to the connection points until it was 

fastening, and then use the Hex key to fasten the one 

screw on each arm, as shown in Figure 2-2. 

 

 
 

 
 

                                                                                                                               

 

 

 

 

Figure 2-2 

2.2 Power-on test before the installation of device 

1.

 

Please make sure that the power requirements are strictly met to avoid permanent damage to the unit. Input voltage: AC 
100~120V/200 ~ 240V. 

Note:

 The tripod turnstile must be connected to the ground (earth). 

2.

 

Power on and wait 30s for the tripod turnstile to finish the self-check program. 

3.

 

Lift the arms manually, as shown in Figure 2-3. 

4.

 

Check whether the tripod turnstile and the LED indicators work properly. 

(If there is any problem, please contact the supplier). 

 
 
 
 
 
 
 
 

Figure 2-3 

3. Equipment Installation 

3.1 Installation conditions 

The equipment must be installed on concrete ground, ensuring that expansion bolts can be secured firmly. 

You are suggested to install an assistant framework or fence to form a passageway, as shown in Figure 3-1. 

 

Figure 3-1 

Lift upwards

 

Tighten the one screw on each 

arm in clockwise direction. 
 

Содержание TS3000 Series

Страница 1: ...TS3000 Series Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Страница 2: ...r Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 38kg Operating Humidity 5 85 Gross Weight 43kg Flow Rate 20 30 passages minute Dimension mm Figure 1 L 940 W 260 H 980 Input Control Sign...

Страница 3: ...arth 2 Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arms manually as shown in Figure 2 3 4 Check whether the tripod turnstile and the LED indicators work...

Страница 4: ...t be connected to the ground earth there is wiring interface near the power switch Figure 3 3 3 3 Installation 1 Drilling holes Drill holes based on the locations of the holes shown in Figure 3 3 2 Fi...

Страница 5: ...splay the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Left J4 Right Indicator To connect a LED screen and indicate whether this pass...

Страница 6: ...t otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alar m Default...

Страница 7: ...card each time this function can be enabled or disabled through number 6 in the DIP switch The description of the bit settings are as follows In the DIP switch number 6 is used to enable or disable t...

Страница 8: ...t the ends of the arm is 40kg See Figure 5 1 When the impact force on the tripod turnstile reaches the designed limit the arms break down first to ensure that the whole equipment is not damaged and th...

Страница 9: ...nts or drop arm solenoid 1 Check whether the stop base and turn plate withstands each other as shown in Figure 6 1 2 Check whether the drop arm solenoid is operating Check the work status of the solen...

Страница 10: ...s any gap at the position shown in Figure 6 1 2 Check whether the drop arm solenoid is totally closed If not power off the equipment and power on it again 2 minutes later The turnstile allows people c...

Страница 11: ...erification Interval 1s 4 Controller Communication TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function...

Страница 12: ...ection Diagram of Mainboard and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to tak...

Отзывы: