background image

11 

 

Attachment 2 Connection Diagram of Mainboard and Access Control Panel 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

: This is a class A product. In a domestic environment this product may cause radio interference in which case the 

user may be required to take adequate measures. 

 

Содержание TS3000 Series

Страница 1: ...TS3000 Series Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Страница 2: ...r Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 38kg Operating Humidity 5 85 Gross Weight 43kg Flow Rate 20 30 passages minute Dimension mm Figure 1 L 940 W 260 H 980 Input Control Sign...

Страница 3: ...arth 2 Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arms manually as shown in Figure 2 3 4 Check whether the tripod turnstile and the LED indicators work...

Страница 4: ...t be connected to the ground earth there is wiring interface near the power switch Figure 3 3 3 3 Installation 1 Drilling holes Drill holes based on the locations of the holes shown in Figure 3 3 2 Fi...

Страница 5: ...splay the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Left J4 Right Indicator To connect a LED screen and indicate whether this pass...

Страница 6: ...t otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alar m Default...

Страница 7: ...card each time this function can be enabled or disabled through number 6 in the DIP switch The description of the bit settings are as follows In the DIP switch number 6 is used to enable or disable t...

Страница 8: ...t the ends of the arm is 40kg See Figure 5 1 When the impact force on the tripod turnstile reaches the designed limit the arms break down first to ensure that the whole equipment is not damaged and th...

Страница 9: ...nts or drop arm solenoid 1 Check whether the stop base and turn plate withstands each other as shown in Figure 6 1 2 Check whether the drop arm solenoid is operating Check the work status of the solen...

Страница 10: ...s any gap at the position shown in Figure 6 1 2 Check whether the drop arm solenoid is totally closed If not power off the equipment and power on it again 2 minutes later The turnstile allows people c...

Страница 11: ...erification Interval 1s 4 Controller Communication TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function...

Страница 12: ...ection Diagram of Mainboard and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to tak...

Отзывы: