background image

10 

The passing is not smooth after the 
turnstile is opened, it encounters resistance 
when pushing the arms, and the arms 
cannot return to the home position after 
they rotate.   

It is caused by the Adjustable Tension Spring. 
Adjust the Adjustable Tension Spring, as shown in Figure 5-3.   

The arms drop during the use. 

It may be caused by the problem of relative components or drop-arm 
solenoid. 

1.

 

Check whether there is any gap at the position shown in Figure 6-1. 

2.

 

Check whether the drop-arm solenoid is totally closed. If not, power 
off the equipment and power on it again 2 minutes later.   

The turnstile allows people continue 
passing one-way side during the use. 

1.

 

Check the Turnstile-opening Solenoid 

2.

 

Check whether the Turnstile-opening solenoid is operating, and 
check whether the Turnstile-opening solenoid is stuck or the Metal 
Shrapnel is broken, as shown in Figure 5-3. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6-2 

 

 

Normal status (closed) of the drop-arm 

solenoid after being powered on.

 

Normal status of the drop-arm solenoid 

after being powered off 

Содержание TS2000 Series

Страница 1: ...TS2000 Series Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Страница 2: ...ndoor and Outdoor shelter Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 46kg Operating Humidity 5 85 Gross Weight 54kg Flow Rate 25 30 passages minute Dimension mm Figure 1 L 1110 W 260...

Страница 3: ...100 120V 200 240V Note The tripod turnstile must be connected to the ground earth 2 Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arms manually as shown in...

Страница 4: ...ting a warning line for card swiping see Figure 3 2 A warning line is suggested to prompt users to swipe cards in a distance which would greatly reduce the probability of equipment failure caused by i...

Страница 5: ...g plate If the mounting plate is not level adjust it by the gaskets provided Note that all the four expansion bolts must be installed properly and two expansion bolts on each column as shown in Figure...

Страница 6: ...1 second Figure 4 1 Descriptions J2 Counter To connect a LED screen and display the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Rig...

Страница 7: ...ally charged objects to connect to any one port of Opening Signal Input otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening...

Страница 8: ...ard each time this function can be enabled or disabled through number 6 in the DIP switch The description of the bit settings are as follows In the DIP switch number 6 is used to enabled or disabled t...

Страница 9: ...enter of the arm is 80kg and at the ends of the arm is 40kg See Figure 5 1 When the impact force on the tripod turnstile reaches the designed limit the arms break down first to ensure that the whole e...

Страница 10: ...or drop arm solenoid 1 Check whether the stop base and turn plate withstands each other as shown in Figure 6 1 2 Check whether the drop arm solenoid is operating and check the work status of the solen...

Страница 11: ...any gap at the position shown in Figure 6 1 2 Check whether the drop arm solenoid is totally closed If not power off the equipment and power on it again 2 minutes later The turnstile allows people con...

Страница 12: ...erification Interval 1s 4 Controller Communication TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function...

Страница 13: ...tion Diagram of Control board and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to t...