Bit Setting Duration Bit Setting Duration

111

5s

011

30s

110

10s

010

40s

101

15s

001

50s

100

20s

000

60s

Note:

The turnstile’s opening duration is set to 5s by default.

4.3.2

Direction Indicator

It is to indicate whether people can pass through the gate. The green arrow means passing is
allowed while the red cross "

X

" means that passing is prohibited. The indicator status can be set with

number 4 and 5 in the DIP switch. The descriptions of the bit settings are as follows:

11

= Passing is allowed in both directions.

10

= One-way forbidden; right passing is allowed.

01

= One-way forbidden; left passing is allowed.

00

= Both ways forbidden.

4.3.3

Continue Passing Function

With the “Continue Passing” function, the turnstile could remember at most 20 swipes of one card at
one time and allows up to 20 people to pass so they don’t have to swipe card each time. This
function can be enabled or disabled with number 6 in the DIP switch. The descriptions of the bit
settings are as follows:

In the DIP switch, number 6 is used to enabled or disabled the

Continue Passing Function

; number

7 is used to set the initial value of

Continue Passing Function

.

Number

6

Number

7

Function

Opening Duration

0

Disabled Disabled

Continue Passing

Function

Please refer to section

4.3.1 Setting the

Turnstile Opening Duration.

1

1

Enabled

Continue Passing

Function

The initial value is 16s, and the

Opening

Duration

= 16 + (N -1) * 6.

0

The initial value is 8s, and the

Opening

Duration

= 8+ (N -1) * 6.

4.3.4

Alarm Function (Optional)

In the DIP K1 switch, number 8 is used to enabled or disabled the

Alarm Function

.

1

= enabled

Содержание TS200 Series

Страница 1: ...ZKTECO CO LTD All rights reserved Thank you for choosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only ...

Страница 2: ...l P a g e 1 About the Manual This manual introduces the operations of TS200 Series Tripod Turnstile product All figures displayed are for illustration purposes only Figures in this manual may not be exactly consistent with the actual products ...

Страница 3: ...key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description This implies about the notice or pays attention to in the manual The general information which helps in performing the opera...

Страница 4: ...IAGRAM 9 FUNCTION DESCRIPTION OF THE TURNSTILE CONTROL BOARD 9 CONNECTION DIAGRAM OF THE ACCESS CONTROLLER 10 DIP K1 SWITCH CONFIGURATION 10 4 3 1 SETTING THE TURNSTILE OPENING DURATION 10 4 3 2 DIRECTION INDICATOR 11 4 3 3 CONTINUE PASSING FUNCTION 11 4 3 4 ALARM FUNCTION OPTIONAL 11 5 EQUIPMENT PRECAUTIONS AND MAINTENANCE 12 PRECAUTIONS 12 MAINTENANCE 13 6 TROUBLESHOOTING 14 ATTACHMENT 1 FACTORY...

Страница 5: ...ifications Input Voltage AC 100 120V 200 240V 50Hz 60Hz Arm Length mm 500 Operating Environment Indoor and Outdoor shelter Dimension mm Figure 1 L 1200 W 280 H 980 Operating Temperature 28ºC 60ºC Package Size mm L 1275 W 370 H 1063 Operating Humidity 5 85 Flow Rate Max 30 passages minute Input Control Signal Dry contact Rated Power 18 W Figure 1 ...

Страница 6: ...gure 2 1 Power on Test before Installation 1 Please make sure that the power requirements are strictly met to avoid permanent damages to the unit Input voltage AC 100 120V 200 240V Note The tripod turnstile must be connected to the ground earth 2 Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arms manually as shown in Figure 2 2 4 Check whether the tripo...

Страница 7: ...3 1 Figure 3 1 Notes 1 When installing the tripod turnstile against the wall please reserve a distance of at least 100 mm in order to open the cover for future adjustment and maintenance 2 The spare space from the end of the arm shall not be greater than 80 mm see Figure 3 1 3 You are also recommended to set a warning line for card swiping see Figure 3 2 The warning line prompts users to swipe car...

Страница 8: ...ing as shown in Figure 3 3 Units of all data is millimeter Power supply and communication wire should go through the inlet Cable protection covers are suggested to use if it is surface mounted Warning The tripod turnstile must be connected to the ground earth there is wiring interface near the power switch Figure 3 3 ...

Страница 9: ...d use a horizontal ruler to test the levelness of the mounting plate If the mounting plate is not levelled adjust it with the gaskets provided Note that all the four expansion bolts must be installed properly as shown in Figure 3 4 Figure 3 4 3 Install the turnstile on the mounting plate and tighten the screws Apply screw securing glue before using and putting gaskets on the screws to adjust the d...

Страница 10: ...ion of the Turnstile Control Board If you are using standard device that without RFID or Fingerprint reader you need to connect access control system to the main board please check the content in this chapter carefully Turnstile control board s diagram as shown in Figure 4 1 Figure 4 1 ...

Страница 11: ... port of Opening Signal Input otherwise will damage the control board DIP K1 Switch Configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alarm Default 1 1 1 0 1 0 0 0 0 ON 1 OFF 4 3 1 Setting the Turnstile Opening Duration Opening duration refers to the period of time from opening to closing once the turnstile receives an open...

Страница 12: ...ion With the Continue Passing function the turnstile could remember at most 20 swipes of one card at one time and allows up to 20 people to pass so they don t have to swipe card each time This function can be enabled or disabled with number 6 in the DIP switch The descriptions of the bit settings are as follows In the DIP switch number 6 is used to enabled or disabled the Continue Passing Function...

Страница 13: ...ables are connected properly this equipment can be immersed under water at a depth of 250 mm but it must not be powered on when it is immersed in water 3 It is highly recommended to set a warning card swiping line to remind passers by to correctly swipe cards at a reasonable distance from the device to prevent passers by from being squeezed 4 It is recommended to place a warning sign at a conspicu...

Страница 14: ...mmended placing warning signs at conspicuous positions for alerting every passersby to pass carefully and in good order Reasonable maintenance consciousness helps to guarantee long term usage of the tripod turnstile Regular maintenance Cleaning and protection liquid dedicated for stainless steel are recommended to wipe the outer shell of the equipment regularly The tripod turnstile used outdoors o...

Страница 15: ...cessful authentication It may be caused by lack of permission or a circuit problem 1 Check whether the user has the permission to pass 2 Use a multimeter to check whether the NO and COM ports of the access control system have a relay signal output 3 Short circuit the ports K1 GND and K2 GND if the turnstile is successfully opened the controller is not normal In this case please refer to Attachment...

Страница 16: ...cation TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function Disabled 8 Alarm Function Disabled Note The Lock Driving Duration is 5 seconds by default Please set it to 1 second Do not connect an electrically charged objects to any ports of Opening Signal Input otherwise it will damage the control board ...

Страница 17: ... g e 16 Attachment 2 Connection Diagram of Control Board and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference so that the user may have to take adequate additional measures ...

Отзывы: