background image

Method 2: Register on ZKBioSecurity software

Please set the IP address and cloud service server address in the Comm. Menu option 
on the device.

2.    Click [

Add

] in operation column, a new window will pop-up. Select Icon type, Area,

      and  Add  to  Level  from  each    dropdowns  and  click  [

OK

]  to  add  the  device.

3.    Click [

Personnel

] > [

Person

] > [

New

] and fill in all the required fields to register

       a new users in the software.
4.    Click [

Access

] > [

Device

] > [

Device Control

] > [

Synchronize All Data to Devices

]

       to synchronize all the data to the device including the new users.

For more details, please refer to the ZKBioSecurity User Manual.

1.   Click [

Access

] > [

Access Device

] > [

Device

] > [

Search Device

] to search the device    

on the software. When an appropriate server address and port is set on the device,

      the searched devices are displayed automatically.

Refresh

New

Delete

Export

Search Device

Device Control

Set up

View and Get Device Info

Communication

Search Device

Search

No device found? Download Search Tools to Local Disk

Total

 

Progress

IP Address

IP Address

Device Type

Serial Number

Searched devices

 

count:2

Number of devices

 

added:1

MAC Address

Subnet Mask

Gateway Address

Serial Number

Device Type

Set Server

Operations

192.168.0.31

255.255.255.0

192.168.0.1

S***********

This device has been added

Add

192.168.10.214

255.255.255.0

192.168.1.1

XXXX000000000

XXXX000000000

SPeedFace-V5L

The current systen communication port is 8088, please make sure the device is set correctly.

Step

 

1

Step

 

2

Step

 

3

Add

Clear Data in the Device when Adding

Device Name

 *

Icon Type

*

Area

*

Add to Level

192.168.4.18

Door

Area Name

[Clear

 

Data

 

in

 

the

 

Device

 

when

 

Adding]

 

will

 

delete

 

data

 

in

 

the

 

device (except

 

event

record), please

 

use

 

with

 

caution!

OK

Cancel

Step

 

4

10

Содержание SpeedFace V5L QR Series

Страница 1: ...art Guide Version 1 0 Due to regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual SpeedFace V5L Q...

Страница 2: ...IWD0 IWD1 WD0 WD1 TX RX TX RX AUX AL AL NC1 COM NO1 BUT GND SEN GND Lock Alarm Exit Button Sensor Auxiliary Input Ethernet Power In Wiegand In Wiegand Out Note Not all products have the function with...

Страница 3: ...l Imaging Temperature Detection Module SpeedFace V5L QR TI Installation Environment Please refer to the following recommendations for installation INSTALL INDOORS ONLY AVOID INSTALLATION NEAR GLASS WI...

Страница 4: ...e palm collection area such that the palm is placed parallel to the device 3 Make sure to keep space between your fingers KEEP EFFECTIVE DISTANCE OF 30 to 50 cm DO NOT KEEP YOUR FINGERS CLOSE Recommen...

Страница 5: ...Avoid direct sunlight 16 C to 35 C 60 8 F to 95 F 30 to 120cm 0 98ft to 3 94ft 0 3 C 0 54 F The recommended operating temperature is 25 C 77 F The recommended distance is 80cm 2 62ft This value is te...

Страница 6: ...Sensor Card Reader 1 2 3 1 5m Attach the mounting template sticker to the wall and drill holes according to the mountingpaper Fixthebackplateonthewallusingwallmountingscrews Attachthedevicetothebackp...

Страница 7: ...Address input the address and OK 8 7 6 RJ 45 5 4 3 2 1 R R 6 1 12V 10 at least 00mA 2 To share the power with other devices use a power supply with higher current ratings Note n A addresses o the serv...

Страница 8: ...nd COM terminals The power can be shared with the lock or can be used separately for the lock as shown in the example with NC Lock below 7 Lock Relay Connection 1 e ice not sharing power with the lock...

Страница 9: ...ccess Controller 12V IWD1 IWD0 GND WD1 WD0 Wiegand card reader connects to the top 4 pins of the wiegand terminal and the last twopinsareusedbytheAccesscontroller asshowninthefollowingfigure Itsendsth...

Страница 10: ...ister a new user The options include User Mgt New User entering the user ID and Name setting User Role registering Palm Face Card Number PasswordandaddingProfilePhoto Main Menu User Mgt User Role COMM...

Страница 11: ...displayed automatically Refresh New Delete Export Search Device Device Control Set up View and Get Device Info Communication Search Device Search No device found Download Search Tools to Local Disk To...

Страница 12: ...to audit Yes No Self service Registration QR Code URL http Server address Port Download QR code image Yes No Enable the declaration of health information Card Management Position Dismissed Personnel C...

Страница 13: ...fthestandbyinterface Note While pairing the device with ZKBioSecurity software Make sure that the option EnableDomainNameisdisabledandthecorrectserveraddressandportareentered ServerAddress SetastheIPa...

Страница 14: ...Event Logs Attendance Photo Blocklist ATT Photo Attendance Search Password Face Palm 1 Gate Control Mode Veri cation Mode Door available time period Normal open time period Master Device Auxiliary in...

Страница 15: ...able capture of unregistered person Trigger external alarm Clear external alarm Exter alarm delay s 255 Update Firmware Display Thermodynamics Figure Main Menu User Mgt User Role COMM System Data Mgt...

Страница 16: ...hetypeof mask thesizeofthefacecoveredbythemask andbangswillaffectthefacialrecog nitioneffect Recommended for indoor use Facial verification for masked individuals will increase FAR Palm verification f...

Страница 17: ...ormal T emperature Record Departmental body temperature daily statistics report Parameters Monthly Event Statistics Report o 40 1 C Mask Name Department Time None 19961107 null 09 50 48 o 40 1 C Mask...

Страница 18: ...e in the phone screen 17 Open the APP enter the IP address or domain name of the server and its port number scan the QR Code of the new APP client After the connection is successful tap on Employee to...

Страница 19: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved...

Отзывы: