RS485 Connection
2008 FC R0HS
FR1200 Connection
System Settings
DIP Settings
FR1200
Do not use
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Distance: More than 200 meters
1.
There are six DIP switches on the back of FR1200, switches 1-4 is for
RS485 address, switch 5 is reserved, switch 6 is for reducing noise on
long RS485 cable.
2.
If FR1200 is powered from ProCapture terminal, the length of wire
should be less than 100 meters or 330 ft.
3.
If the cable length is more than 200 meters or 600 ft., the number 6
switch should be ON as below
Select > Serial Comm
Select > Comm
Select > RS232/485
Change > RS485 to (master unit)
PIN DESCRIPTION WIRE
1
+
1
2V
Red
2
GND
Black
3
IWD1
Green
4
IWD0
White
5
6
7
BEEP
Brown
GLED
Gray
RLED
Blue
PIN DESCRIPTION WIRE
1
WD0
Green
2
WD1
White
3
GND
Black
4
RXD
Gray
5
6
GND
Black
7
8
485B
Yellow
485A
Blue
TXD
Purple
1
7
RLED
RJ45-1
COM1
+12V
BUT
BELL+
BELL-
RJ45-3
GLED
AL-
IWD0
NO1
GND
RJ45-2
IWD1
NC1
GND
SEN
RJ45-6
BEEP
AL+
Ethernet
Alarm
Wiegand In
Output
Wiegand Output
RS485
Lock
Bell
Power Out
Sensor
Button
RXD
GND
WD1
TXD
485A
GND
485B
WD0
+12V
GND
GND
AUX
Auxiliary In
RS232
Power In
}
}
}
}
}
}
}
}
}
}
}
}
}
}
1
8
2.4 Inch TFT Time Attendance
&
Access Control Terminal INSTALLATION GUIDE