background image

This  manual  is  proprietary  information  of  Open  Options, 

LLC

.  Unauthorized  reproduction  or 

distribution  of  this  manual  is  strictly  forbidden  without  the  written  consent  of  Open  Options, 

L

LC

. The information contained in this manual is for informational purposes only and is subject

 

to  change  at  any  time  without  notice.  Open  Options,  L

LC

.  assumes  no  responsibility  for

 

incorrect or outdated information that may be contained in this publication.

DNA Fusion

TM

 and 

SSP

TM

 a

re

 trademark

s

 of Open Options, 

L

LC

.

The 

DNA  Fusion

TM

  Access  Control  Software  and 

SSP

TM

  Security  System  Processor 

use 

equipment  that  generates, 

uses

, and  radiate

s

 radio frequency  energy

.

 

If

 not installed  and

 

deployed 

in  accordance  with  th

e  guidelines  of  this  installation

 manual,

  they  may  cause 

h

armful

 

interference

 

to

 

radio

 

communications.

 

Operation

 

of  this  equipment  in  a  residential

 

area

 

may  cause  harmful  interference

,  i

n  which  case  the  user

 

will be required to correct the

 

interference at the

ir own

 expense.

The

  DNA  Fusion

TM

  Access  Control  Software  and  SSP

TM

  Security  System  Processor 

shall

 

be

 

installed

 

in

 

accordance

 

with

 

this

 

installation manual

 

and

 

in

 

accordance

 

with

 

the

 

National

 

Electric

 

Code

 

(N.E.C),

 

ANSI and

 

NFPA 70 Regulations and recommendations. 

P

ublish

 Date: 

 

August

 

25

, 20

20

 

Manual Number:

 

ZQSG

-

1.0

©

 

Copyright 2002-20

20

 Open Options, 

LLC

.

  All rights reserved.

Warranty 

All Open Options products are warranted against defect in materials and workmanship for 

two

 

year

s

 from the  date  of  shipment.   Open Options  will  repair  or  replace  products  that  prove

defective and are returned to Open Options within the warranty period with shipping prepaid. 
The  warranty  of  Open  Options  products  shall  not  apply  to  defects  resulting  from  misuse, 
accident, alteration, neglect, improper installation, unauthorized repair, or acts of God.  Open 
Options shall have the right of final determination as to the existence and cause of the defect. 
No other warranty, written or oral is expressed or implied. 

16650 Westgrove Dr

 | Suite 

150

 

Addison, TX 75001

Phone: (972) 818-7001 

Fax (972) 818-7003 

www.

ooaccess

.com 

Содержание SF1005-V+

Страница 1: ...OPEN OPTIONS A C C E S S T E C H N O L O G Y ZKTeco Quick Start Guide...

Страница 2: ......

Страница 3: ...to correct the interference at their own expense The DNA FusionTM Access Control Software and SSPTM Security System Processor shall be installed in accordance with this installation manual and in acc...

Страница 4: ...rants that it has the sole right to license the Software to Licensee Upon registration by the Licensee Open Options further warrants that the media on which the Software is furnished will be free from...

Страница 5: ...er the device For access controller communication wire the Wiegand Out cables to the DAT CLK D1 D0 terminal of the SSP controller NOTE For user registration purposes a wiegand reader needs to be wired...

Страница 6: ...tion Environment Follow these recommendations for the physical installation of the reader Install Indoors Avoid Glass Refraction Avoid Direct Sunlight and Exposure Keep Away from Heat Source Effective...

Страница 7: ...12V GND terminals to power the device 2 To establish communication between the SF1005 V to the controller sub controller wire Wiegand Out terminals to the DAT D0 CLK D1 Reader Port 1 or 2 terminals on...

Страница 8: ...tions Confidential ZKTeco SF1005 V Quick Start Guide Additional Wiring To wire any additional features to the SF1005 V see the diagrams below ZKTeco SF1005 V Wire Terminals Exit Buttons Sensors and Al...

Страница 9: ...Page 5 ZKTeco SF1005 V Quick Start Guide Open Options Confidential Lock Relay Connection RS485 and RS232 Connection...

Страница 10: ...Page 6 Open Options Confidential ZKTeco SF1005 V Quick Start Guide This Page Intentionally Left Blank...

Страница 11: ...the SF1005 V is wired and powered begin adding users to the device See the following steps for instructions on adding users 1 On the SF1005 V select the Main Menu icon 2 Select User Mgt 3 Select New U...

Страница 12: ...t one form of verification must be added before the user s name is saved to the SF1005 V In the New User screen 1 If a wiegand reader was configured with the SF1005 V add the card information to the B...

Страница 13: ...lect Palm b Present the new user s palm to the SF1005 V c Follow the directions on the Enroll Palm screen The user s palm will be authenticated once the progress bar at the bottom spans from one side...

Страница 14: ...ect Face b Present the new user s face to the SF1005 V c Follow the directions on the Enroll Face screen The user s face will be registered once the progress bar at the bottom spans from one side of t...

Страница 15: ...ode 2 Select an option shown on the screen Additional Parameters Additional parameters can be set in the SF1005 V Parameters like temperature screening can be enabled through the Detection Management...

Страница 16: ...ential ZKTeco SF1005 V Quick Start Guide 4 If needed select Enable temperature screening with infrared Enabling temperature screening allows for monitoring of the user s body temperature 5 If needed s...

Страница 17: ...Fusion 2 Expand SIO subcontroller On board subcontroller tree 3 Right click on a DNA Access Control Reader and select Add Door Use Default Adding a New User to Personnel Properties If a New User needs...

Страница 18: ...16650 Westgrove Dr Suite 150 Addison TX 75001 Phone 972 818 7001 Publish Date August 25 2020 DNA Fusion Version 7 8 0 5 Manual Number ZQSG 1 0 www ooaccess com...

Отзывы: