background image

 

SBTL5000 series User Manual 

 

P a g e

 | 

10

 

17.

 

Select anti-pinch area 

No anti-pinch (Default). 

All IR areas for anti-pinch.  

18.

 

Master device speed compensation

 

 

0~20 (The default is 0). 

19.

 

Slave device speed compensation

 

 

0~20 (The default is 0). 

20.

 

Swiping card mode 

Allow to swipe card in passage (Default). 

Not allow to swipe card in passage. 

21.

 

Version 

V6.0.3. 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SBTL5000 series

Страница 1: ...User Manual Swing Barrier SBTL5000 series Applicable Models SBTL5000 5200 5011 5211 5022 5222 Version 1 1 Date August 2019 ...

Страница 2: ...composition of the product 3 1 7 Specification 4 2 Installation of the Product 4 2 1 Installation notes 4 2 2 Installation position of the swing barrier 5 2 3 Cables installation and fixing 5 3 Menu Introduction 7 3 1 Function introduction 7 3 2 Menu introduction 7 3 3 Functions introduction of wiring and terminal 11 4 Troubleshooting 12 5 Product Maintenance 13 5 1 Chassis maintenance 13 5 2 Move...

Страница 3: ...00 SBTL5211 SBTL5222 1 2 Chassis design and dimensions SBTL5000 series is with SUS304 housing provides simple and beautiful design with anti corrosion It provides legal access to the persons while eliminating illegal personnel access In case of emergency it ensures that evacuation passage runs smoothly and is convenient for personnel SBTL5000 s appearance and dimensions are as shown in Figure 1 2 ...

Страница 4: ...signals and sends executive commands to the direction indicator the electric motor and the alarm Infrared sensor It detects the position of a pedestrian and plays the role of safety protection Direction indicator This indicator displays the current status of the sign at the lane and directs the pedestrian to pass through the lane in a safe and orderly manner Alarm The alarm gives an alarm voice if...

Страница 5: ...d by the pedestrian is invalid the system will stop the pedestrian and give an audible alarm until the pedestrian retreats from the lane The pedestrian can pass through the lane only after a valid card is read by the card reader 1 6 System composition of the product The single lane management system is composed of two single core swing barrier turnstile The multi lane management system is composed...

Страница 6: ...r turnstile be installed on a horizontal solid platform with 50mm to 100mm in height 2 It is also recommended that the swing barrier turnstile should not be used in corrosive environment 3 Make sure the protective ground wire of the system is reliably connected to avoid personal injuries or other accidents 4 After installation check whether connection is reliable at the connecting points of the pr...

Страница 7: ...ase refer to the drawing showing the mounting holes The input voltage for this swing barrier turnstile is AC100 120V 200 240V and its master and slave are connected by a 5 core cable signal and a 2 core cable power When installing this swing barrier turnstile the user only needs to connect it to the corresponding ports Note that the PVC conduits are buried 100mm under the ground with the height of...

Страница 8: ...all the screws Place the swing barrier turnstile according to the sizes and positions as shown in the figure before installation and fixing Connect the online cables and perform the power on test If the test is OK tighten the screws It is recommended that a warning line be marked out on the ground after the machine is installed so as to prompt the pedestrian to stand behind the warning line when s...

Страница 9: ...e the value ENT to enter menu setting item or confirm the current modified value ESC to return to the previous menu or to cancel the current operation Figure 3 1 3 Operation and instruction of menu Press the ENT button enter the password input interface the default password is UP UP DOWN DOWN DOWN DOWN If any step fails please press the ESC button to get back After entering the menu press UP or DO...

Страница 10: ...card Left swiping card Right forbidden Left forbidden Right free Left free Right forbidden Bi direction forbidden 3 Open duration 5 60s The default is 10s 4 False direction entry Close door and voice alarm Voice alarm Default Alarm disabled 5 Speed of barrier closing and opening Low speed Middle speed Default High speed 6 Anti tailgate Alarm disabled Voice alarm Default Close door and voice alarm ...

Страница 11: ...default is 3 11 Fire signal setting Right opening Default Left opening Disable 12 System working mode Working mode Default Test mode Factory reset 13 Volume setting Disable 1 16 The default is 5 14 Exchange voice of door opening No Default Yes 15 IR anti pinch setting Disable Stop turning for anti pinch Default Open the barrier for anti pinch 16 Memory function Disable Default Enable ...

Страница 12: ...ti pinch Default All IR areas for anti pinch 18 Master device speed compensation 0 20 The default is 0 19 Slave device speed compensation 0 20 The default is 0 20 Swiping card mode Allow to swipe card in passage Default Not allow to swipe card in passage 21 Version V6 0 3 ...

Страница 13: ...e the swing barrier of the machine is opened with power from the backup battery and is no longer closed Right open DOWN button left open UP button Controls the barrier to open to left or right side Access control power supply Supplies power for the access board RS485 communication port Receiving external signals Master slave terminal It is connected to the master and slave boards to transfer signa...

Страница 14: ...ered exit to safety 4 Troubleshooting Number Failure description Analysis and solution 1 No response from direction indicator or indication is not correct Check whether the connection of the roof lamp is correct or not 2 After swiping the card there is only a swing arm action Check the master and slave machine type setting and the 5 core 2 core connection line 3 Barrier open after a long time no c...

Страница 15: ...loose if found loose adjust the position of the motor to make the belt tight Check and tighten others connection parts 5 3 Power maintenance Cut off power supply before maintenance Check whether the plug is loose if found loose tight it Do not replace the connection position at random Check whether the external power supply is exposed timely wrap it Whether there is any leakage do timely treatment...

Страница 16: ...Copyright 2019 ZKTECO CO LTD All rights reserved ZK Building Wuhe Road Gangtou Bantian Buji Town Longgang District Shenzhen China 518129 Tel 86 755 89602345 Fax 86 755 89602394 www zkteco com ...

Отзывы: