Detection Management
6.7
Click
Detection Management
on the System interface.
Item
Description
Enable temperature
screening with
infrared
To enable or disable the infrared temperature measurement function.
When this function is enabled, before access granted, users must pass the
temperature screening in addition to identity verification.
To measure body temperature, users’ faces must be aligned with the
temperature measurement area.
High temperature
alarm threshold
To set the value of the alarm threshold of high body temperature.
When the temperature measured during verification is higher than the set
value, the device will give a prompt and audio alarm.
The default alarm threshold is 37.30
℃
.
Low temperature
alarm threshold
To set the value of the alarm threshold of low body temperature.
When the temperature measured during verification is lower than the set
value, the device will give a prompt and audio alarm.