background image

 

10   CMP-100A User Manual 

4 Operation and Maintenance Instructions 

4.1 Operation Instructions 

 

Before using the product, be sure to check whether the supply voltage matches the product, that is, 220 V ± 

10%. Considering under-voltage in some regions, the product can still maintain reliable working performance 

when the voltage drops to as low as 180 V. 

 

To open the gate bar, press the remote controller or the “Rise” button on the remote controller. The gate bar 

rises automatically and stops automatically after it arrives in the specified position. 

 

To close the gate bar, press the remote controller or the “Fall” button on the remote controller. The gate bar 

falls automatically and stops automatically after it arrives in the specified position. 

 

During fall of the gate bar, if a vehicle or person passes by the barrier gate, press the “Rise” button. The gate bar 

immediately runs towards the rise direction. Or press the “Stop” button. The gate bar stops. (Note: When the 

product is working properly, do not press the “Stop” button.) 

 

When power failure occurs, if the gate bar is in the horizontal state, open the door of the chassis and roll the 

gate bar upward by using the handle. After the power supply recovers, directly press the “Fall” button. The gate 

bar falls automatically and recovers. 

4.2 Safety Precautions 

 

To guarantee safe use of the product, the power supply for the product must use a socket that provides 

leakage protection. 

 

Operators must pay attention to the following: Do not place any article under the gate bar; do not make any 

vehicle, person, or animal pass by the gate when the gate bar is operating. 

4.3 Maintenance Instructions 

 

Wipe off dust and oil stains on the surface of the chassis using a soft fine cloth and keep the surface of the 

chassis clean. 

 

Regularly check whether cable connections on the control panel are not loose or the contact is proper and 

Содержание CMP-100A

Страница 1: ...1 F16 Quick Start Guide User Manual Version 1 0 Date May 2019 CMP 100A ...

Страница 2: ...ications 3 2 3 Working Principle 3 2 3 1 Movement Structure 4 2 3 2 Description of Spring Pull Holes 4 2 4 Product Dimensions 6 2 5 Wiring Diagram 7 3 Installation and Commissioning 8 3 1 Installation Instructions 8 3 2 Specific Operation 8 4 Operation and Maintenance Instructions 10 4 1 Operation Instructions 10 4 2 Safety Precautions 10 4 3 Maintenance Instructions 10 4 4 Fault Analysis and Trou...

Страница 3: ...tly used the protection system controls temperature rise of the motor which makes the motor less likely to be burned The manual gate opening mechanism enables the hand wheel of the motor to automatically lift and lower the gate bar in the case of power failure 1 2 Control System The product adopts a digital chip technology and integrates the anti smash ground sensing and IC interfaces thereby prov...

Страница 4: ... avoid damage caused by mistake Ground sense anti smash During fall of the gate bar if a ground sense signal is received the gate bar is automatically lifted and does not fall during the trigger period After the ground sense signal recovers the gate bar automatically falls to ensure safety Opening prioritized anti smash In the case of any emergency during fall of the gate bar the gate bar executes...

Страница 5: ...age AC 220 110 V 50 60 Hz Rated power 90 W Operating temperature of the motor C 30 C C 80 C Chassis weight 55 Protection grade IP44 Height Between the Bar Center and the Ground 830 Remote control distance Not shorter than 30 m 2 3 Working Principle The mechanical power produced by the motor drives the output shaft through the turbine and worm reducer and transfers motion to the handle of the bar t...

Страница 6: ...oning and installation according to the length 6 m 5 m or 4 m of the gate bar the arm of force between spring pull holes and the main shaft and the spring tension can be changed to make the gate bar achieve balance without the need to replace the spring When the length of the gate bar is changed adjust the pull hole of the spring again as shown in the figure Pull holes of the spring as shown in th...

Страница 7: ...CMP 100A User Manual 5 Arm hole for a 6m bar Arm hole for a 5m bar Arm hole for a 4 5m bar Arm hole for a 4m bar ...

Страница 8: ...6 CMP 100A User Manual 2 4 Product Dimensions ...

Страница 9: ...CMP 100A User Manual 7 2 5 Wiring Diagram ...

Страница 10: ... different cable pipes Install expansion screws depending on actual accessories in the list in the position for installing the barrier gate and firmly fix the barrier gate before using it Roll the gate bar to the horizontal position by using the handle determine the position for installing the fork bar at the tail of the gate bar and fix the fork bar using screws this operation is not required if ...

Страница 11: ...tall and fasten the expansion screws 3 Installing the Gate Bar After the chassis of the barrier gate is fastened install the gate bar in the position of the bar handle fasten the gate bar using the screws delivered with the product and determine that the gate bar does not tilt To install the fork bar after debugging the horizontal and vertical states roll the gate bar to the horizontal position by...

Страница 12: ...se button The gate bar immediately runs towards the rise direction Or press the Stop button The gate bar stops Note When the product is working properly do not press the Stop button When power failure occurs if the gate bar is in the horizontal state open the door of the chassis and roll the gate bar upward by using the handle After the power supply recovers directly press the Fall button The gate...

Страница 13: ...Method Test Result Solution The gate bar cannot rise or fall 1 Check whether the power socket provides 220 V voltage by using an electroprobe or the 250 voltage range of a multimeter No Check the mains supply 2 Power off the product and test both ends of the power plug to determine whether they are connected by using the Rx1 range of a multimeter If they are not connected the fuse or power transfo...

Страница 14: ... heard from the chassis Check whether the bearing and the active connection part are abnormal Yes Lubricate the bearing and active connection part or replace the bearing The gate bar does not fall onto the specified position Check whether the travel switch is properly adjusted and whether the travel flange is loose Yes Adjust the position of the travel controller and fasten the travel flange The g...