ZK-RFID102 UHF RFID Reader User's Manual V2.0
34
8.4.7 Acousto-optic Control
The host sends this command to control the LED lights flash and buzzer tweet.
Command:
Len
Adr
Cmd
Data[]
CRC-16
ActiveT
SilentT
Times
0x07
0xXX
0x33
0xXX
0xXX
0xXX
LSB
MSB
Parameter Connect:
ActiveT:
LED flash and buzzer tweet time. (
ActiveT
*50ms), the default value is 0. 0<=
ActiveT
<=255.
SilentT:
The LED and the buzzer silent time (
SilentT
*50ms), the default value is0. 0<=
SilentT
<=255.
Times:
LED flash and buzzer tweet times (0<=
Times
<=255), the default value is0.
Respond:
Len
Adr
reCmd
Status
Data[]
CRC-16
0x05
0xXX
0x33
0x00
——
LSB
MSB
8.4.8 Set Wiegand
The host sends this command to change Wiegand parameter of the reader. The value is stored in the reader’s
inner EEPROM and is nonvolatile after reader powered off.
Command:
Len
Adr
Cmd
Data[]
CRC-16
Wg_mo
de
Wg_Data_I
nteval
Wg_Pulse_Wi
dth
Wg_Pulse_In
teval
0x08
0xXX
0x34
0xXX
0xXX
0xXX
0xXX
LSB
MSB
Parameter Connect:
Wg_mode:
Bit0: Select Wiegand format interface.
=0 Wiegand 26bits format interface.
=1 Wiegand 34bits format interface.
Bit1: High-bit first or Low-bit first.
=0 High-bit first.
=1 Low-bit first.
Bit2~Bit7: RFU. Default value is zero.
Wg_Data_Inteval:
Sending Data Delay (0 ~255)*10ms, the default value is 30.
Wg_Pulse_Width:
Data pulse width (1 ~255)*10us, the default value is 10.
Wg_Pulse_Inteval:
Data pulse interval width (1 ~255)*100us, the default value is 15.