ZK-RFID102 UHF RFID Reader User's Manual V2.0
11
Length
of
Data[]
+5
0xXX
0x51
0X15
……..
LSB+MSB
Return before
Inventory
finished
Return status 0x15 to host
when the reader executes
an Inventory command and
gets some complete
6B
tags’
UID
before
user-defined
Inventory-ScanTime
finished.
Length
of
Data[]
+5
0xXX
0x51
0x16
……..
LSB+MSB
Inventory-Sca
n-Time
overflow
Return status 0x16 when
the reader executes an
Inventory command and
does not get all
6B
tags’
UID before user-defined
Inventory-ScanTime
overflows.
Length
of
Data[]
+5
0xXX
0x51
0x17
……..
LSB+MSB
More Data
Return status 0x17 when
the reader executes an
Inventory command and
gets many
6B
tags’ UID,
Data can not be completed
within in a message, and
then send in multiple.
Length
of
Data[]
+5
0xXX
0x51
0x18
……..
LSB+MSB
Reader
module flash
is Full
Return status 0x18 when
the reader executes an
Inventory command and
gets
6B
tags’ UID too
much,
more
than
the
storage capacity of reader.
5
0xXX
0xXX
0x19
__
LSB+MSB
Not Support
Command Or
Access
Password
Return status 0x19 when
the tag can’t set EAS
Alarm. There may be the
tag does not support the
command, or the tag’s
access password be zero.
5
0xXX
0xXX
0xF9
__
LSB+MSB
Command
execute error
Return status 0xF9 when
Command execute error
5
0xXX
0xXX
0xFA
__
LSB+MSB
Get Tag, Poor
Communicati
on, Inoperable
Return status 0xFA when
there are some tags in the
effective field, but Poor
Communication
between
reader and tag.
5
0xXX
0xXX
0xFB
__
LSB+MSB
No Tag
Operable
Return status 0xFB when
there is no tag in the
effective field.