http://www.zketech.com
EBC-A05 User Manual
Copyright (C) 2006-2015 ZKE Technology
First line: mode and discharging power setting
Second line: cut-off voltage (testing automatically stops when voltage reaches below this value)
the maximum testing time setting (no time limit if being set 0).
3) Standard charging
First line: mode and charging current setting. Modes include: NiMH, NiCd, LiPo, LiFe, Pb
Second line: batteries numbers (plumbic acid: 2V for each battery), charging time (no time
limit if being set 0) and auto mode setting:
²
NOR
–
normal mode, charging will finish soon.
²
AUTO
–
automatically finish the
“
charging-discharging-charging
”
process.
When cursor is on AUTO, a long press on
“
ON
”
and you will move to the second step of auto
discharging setting.
The first parameter: discharging current; the second parameter: cut-off voltage; the third
parameter: interval between step switches (a 5-10 minute waiting time is suggested in a switch
between charging and discharging to cool the battery).
4) Custom charging
First line: mode and charging current setting
Second line: CV voltage, cut-off current (testing stops when the voltage reaches below this
value, can be set above 0.06A) and automatic mode setting (same setting as standard charging).
5) Fixed voltage output
Select
“
CHG-PWR
”
for fixed voltage output and don
’
t need to set any other parameter. The
mode turns off if the current becomes 0 within 10 seconds of testing.
In setting mode, a long press on
“
SET
”
button to save data and return to testing interface.
When setting completes, press
“
ON
”
button on the testing interface and testing starts.
4.4 Setting examples