background image

                                                                                             

           

  http://www.zketech.com 

 

                                                       

EBC-A05 User Manual      

                    Copyright (C) 2006-2015 ZKE Technology 

The first line shows testing mode, voltage and current. Testing modes include: 

²

 

CC 

 constant current discharging 

²

 

CP 

 constant power discharging 

²

 

Ni   

 NiMH/NiCd charging 

²

 

Li   

 LiPo/LiFe charging 

²

 

Pb   

 plumbic acid battery charging 

²

 

CV 

 custom constant voltage charging 

²

 

PW 

 fixed voltage output (5V/2A) 

The  second  line  shows  working  process,  working  time  (in  minute)  and  capacity  (automatic 
switch between 0000mAh and 00.00Ah).   

Working process reads OFF when the test stops and DSC or CHG in testing.  It shows AT1 if 
you choose automatic charging/discharging and 1 means the step 1 of current testing.   

A short press on the 

SET

 button and the display changes to power and energy.   

 

In automatic 

charging-discharging-charging

 test, you can check test results of each step by a 

short press on 

INC

 or 

DEC

 buttons.   

 

Press the 

ON

 button to start testing and one more press to stop.   

You  can  open  setting  interface  by  press  on  the 

SET

  button  for  2  seconds  in  the  stop  state 

(This function is invalid when the tester being connected with the PC software). 

4.3 Setting Interface 

The cursor default is on mode setting. Press the 

SET

 button to move it to the value you want 

to set up. One press on 

SET

 and the cursor moves one digital toward right. Press the 

INC

 

and 

DEC

 buttons to modify the value. Press the 

ON

 button the move to the next item.  It 

will go back to the limit value if your setting exceeds the allowed range.       

1) CC discharging 

 

First line: mode and discharging current setting.   

Second line: cut-off voltage (testing automatically stops when voltage reaches below this value) 
and the maximum testing time setting (no time limit if being set 0). 

2) CP discharging 

 

   

Содержание EBC-A05

Страница 1: ...http www zketech com EBC A05 User Manual Copyright C 2006 2015 ZKE Technology Multifunction Electronic Load EBC A05 User Manual ...

Страница 2: ... battery or battery packs up to 10V at 0 1 3 00A Max charging current Power current 0 5A Standard Charging Support NiMH NiCd LiPo LiFe and Pb batteries CV Charging Support custom CC CV charging Fixed Output 5V 2A output support charging portable power banks and cell phones 5 Discharging 0 30 00V 0 1 5 00A max power 60W and automatic current limiting above CC Discharging Discharging a relatively un...

Страница 3: ... negative poles of the test objects working as the voltage channel in voltage tests This way of using four individual cables will help eliminate the effect of wires on the test result and improve the test precision 3 2 PC Connection The tester can be connected with a computer through a designated USB TTL cable 3 3 Input Power The tester works on a power supply of above DC 12V 3 5A and interface sp...

Страница 4: ...rging discharging charging test you can check test results of each step by a short press on INC or DEC buttons Press the ON button to start testing and one more press to stop You can open setting interface by press on the SET button for 2 seconds in the stop state This function is invalid when the tester being connected with the PC software 4 3 Setting Interface The cursor default is on mode setti...

Страница 5: ...e second step of auto discharging setting The first parameter discharging current the second parameter cut off voltage the third parameter interval between step switches a 5 10 minute waiting time is suggested in a switch between charging and discharging to cool the battery 4 Custom charging First line mode and charging current setting Second line CV voltage cut off current testing stops when the ...

Страница 6: ...arging 5 Precautions 1 Positive and negative connections should not be reversed 2 Always use the tester within the allowed range 3 The maximum charging current should be set below power current 0 5A 4 This manual is applicable to firmware 08 24 Please download the latest software for a upgrade if your version is released earlier than the date 5 PC software http zke2006 blog 163 com blog static 199...