inPulse & and ZKBioSecurity 3.0 Quick Start Guide
Lock Relay Connection
Device Not Sharing Power with the Lock
Notes:
1.
The system supports
NO LOCK
and
NC LOCK
. For example the
NO LOCK
(normally opened
at power on) is connected with ‘
NO1
’ and ‘
COM1
’ terminals, and the
NC LOCK
(normally
closed at power on) is connected with ‘
NC1
’and ‘
COM1
’ terminals.
2.
When electrical lock is connected to the Access Control System, you must parallel one
FR107 diode (equipped in the package) to prevent the self-inductance EMF from affecting
the system.
Do not reverse the polarities.