Installation Guide for SCR100 Device
I
.
Install device
II
.
Access
control system overview
RS232/RS485
Converter
Card
reader
Release
button
Alarm
Lock
Door
sensor
!
Warning: Don’t connect wires with power on!
III
.
Connect
to
door
lock
1
)
device and lock share power supply
NC lock
NO lock
Notice:If lock’s working power is
DC12V,
and working current is least 1000mA less
than that of access
control device power
supply, wiring
with sharing power supply
can be
adopted.
Notice: Wiring with lock power
supplied
independently
is recommended for the
following
states:
1) Lock’s working power is DC 12V,
power’s current is
device
not 1A more
than that of lock.
2)Lock’s standard voltage is not
DC12V.
3)The distance between lock and
device
is long.
NO lock
NC lock
Ⅳ
.
Connection with other device
Alarm
Alarm
power
Release
button
Door sensor
2
)
device
and
lock
don’t
share
power
supply
DC Power
DC Power
DC Power
1)Post the mounting template on
the wall. Drill holes according to
the marks on the template.(Holes
for screw and wiring)
3) Take away the screw on
the bottom of device
2)Take off the water-proof cushion
5)Fix the cushion and plate on
the wall
4) Release the mounting plate
6) Fix the device with the plate
after all wiring completed
⑤
Access
control device can be connected with external out-go
switch, which provides convenience to open door from the inside.
①
When a registered person verified, the access
control device
will export signal to open the door.
②
Door sensor will detect on-off state to sense
whether the door
is opened by accident or the door is not closed well, alarm will
③
If access control device is torn down illegally,
or door sensor
is abnormal, or menace alarm gives off, the device will export
④
Connect a Weigand reader to work as a controller.
⑥
Access control software to manage multi devices
via RS485
Access control system
alarm signal.
or TCP/IP.
The device could connect to NC or NO locks, the connection terminal is not same, please according to the following
diagram to make connection.
1)The rating output of the alarm no more
than DC12V.
The device’s working voltage is DC12V, with
working current 500mA,standby current 50mA .
Make sure the connection as the diagram(
Don’t
connect the poles in reverse.
).
Ⅴ
.
Power connection
be given off under
abnormal condition.
Notice:
2)The device has no bell button
,
so BELL
+
and BELL-
terminals don’t work temporarily.
+
-