Parts in the battery box, (Fig.13.22):
• Flip down support tray for 2 x 12V batteries.
• 2 x battery looms with fuse and ring terminals.
• Battery link harness with red and grey connectors.
Accessing the Batteries
• Take of the rear cover (Fig.13.17).
• Lift the controller plate up, (Fig.13.17).
• Fold the battery support plate down (Fig.13.18).
• Disconnect the power plug from the control box,
(Fig.13.8). Pull the battery out, (Fig.13.19).
• Disconnect the Grey connectors.
• Pull the second battery out.
• Disconnect the Grey connector.
To fit the batteries reverse the above procedure.
CAUTION!
Handle the batteries using the straps provided.
Always use correct lifting techniques as batteries are heavy.
The two battery looms are identical. One is required to be
connected to each battery:
• To disconnect the batteries, lift up the insulator sleeve
& use 11.0 mm spanner to undo the bolt. Always fit the
insulator sleeve when reinstalling, (Fig.13.20).
• The red wire containing the 100 A fuse connects to the
battery Positive (+) terminal, (Fig.13.21).
• The other black wire connects to the battery Negative (-)
terminal, (Fig.13.20)
• The battery terminals must be covered after connection
with the caps provided on the cable.
• Both batteries are fitted to the battery tray with the
terminals rear-most, so that the grey connectors can be
mated with the battery link harness.
• Ensure the link harness is secured in the slots provided
in the tray.
• If you are in any doubt, please contact your Sunrise
Medical authorised dealer.