OPERATION
28
ZI-RBMA1500
15.2
Handling
15.2.1
Switch the machine on / off
Switch the machine on
•
Open the electric panel cover (2) with the nut spinner (1).
•
Set the motor protection switch (3) to position (I).
•
Connect the machine to the mains supply.
Switch the machine off
•
Disconnect the machine from the mains supply.
•
Open the electric panel cover (2) with the nut spinner (1).
•
Set the motor protection switch (3) from position (I) to position
(0).
NOTE:
In dangerous situations, press the emergency stop switch (1).
15.2.2
Control panel
1.
P1 button
Adjustment for bent bar bending
2.
P2 button
Adjustment for set-square bending
3.
P3 button
Adjustment for hook bending
4.
Emergency stop switch
Stops the machine by interrupting the power supply in an emer-
gency.
5.
Prog. On-OFF
For programming serial bending. A maximum of nine bending
angles can be entered.
6.
MAN-AUTO button
Provides the choice between the manual and automatic opera-
tion of the machine.
7.
Direction of rotation switch
Bending disc rotates clockwise = recommended direction
of rotation.
Bending disc rotates counter clockwise.
15.2.3
Rotation direction of the bending disc
•
To check the rotation direction, set the MAN-
AUTO switch on the control panel to the "MAN"
position and afterwards depress the foot pedal.