OPERATION
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
27
ZI-COM24E / ZI-COM50E
14
OPERATION
Device to be operated in a perfect state only. Inspect the device visually every time it is to be used.
Check in particular the safety equipment, electrical controls, electric cables and screwed connection
for damage and if tightened properly. Replace any damaged parts before operating the device.
14.1
Operation instructions
W A R N I N G
Perform all machine settings with the machine being
disconnected from the power supply!
N O T I C E
The oil level in the compressor pump has to be checked before each use
The machine should be set up near the working consumer. Avoid long air lines
and long supply lines (extensions).
Make sure the intake air is dry and dust-free.
Do not set up the machine in damp or wet areas.
The machine must be operated on firm, level ground
Safety valve must be closed before the start
When removing the hose coupling, hold the coupling piece of the hose is by
hand. So the injury from rebounding hose is avoided
14.2
Operation
Switch on:
Pull out the On-Off-switch
Switch off:
Press back in the On-Off-switch
Setting output pressure:
The output pressure can be set with
the pressure regulator
Output pressure:
The output pressure is shown on the
manometer output pressure
Air tank pressure:
The air pressure is shown on the
manometer air pressure
Output:
To connect a device place the union joint into the coupling. The sleeve will go to starting position
automatically. To disconnect pull the sleeve backwards and remove the hose.