ASSEMBLY
Z.I.P.P.E.R Maschinen GmbH
www.Zipper-maschinen.at
Seite26
ZI-GHAS2800
13.1
Start up
Make sure that the device is completely and correctly assembled.
Set the shredder for use on firm, horizontal ground (tipping).
Use the device only in the open. Keep a safe distance (at least 2 m) from a wall or other
rigid object.
Check before each use:
-
the connection cables for defects (cracks, cuts, etc.) do not use damaged cables
-
the device for damage (see Safety)
-
that all screws are tightened
13.2
Electrical Connection
The supply voltage must comply with the specifications that are listed on the nameplate of
your harvester. Chopper with a nominal value of 230 V can be connected to a mains voltage of
230V. The chopper is to be supplied via a residual current protective device with a tripping
current not exceeding 30 mA. An extension cord with too small a cross section causes a signifi-
cant reduction in the efficiency of the machine. For cables with a length of up to 25 m, a diam-
eter of at least 3 x 1.5 mm
2
is required, for cables with a length of about 25 m, the cross sec-
tion must be at least 2.5 mm
2
Note!
When starting (start) this equipment, a brief voltage drop occur, especially in poor network
quality. These dips can affect other devices (eg flicker of a lamp). For a line impedance Z
max
0.42HM such disturbances are not expected. (Please contact you their local power company for
further information).
Autogoods “130”
130.com.ua