MAINTENANCE
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
27
ZI-STE6700DH & ZI-STE7500DSH
If the voltage (see voltmeter) is too high or too low, adjust the speed level. If a problem occurs,
stop the generator and take care of the problem.
At the DC-module (12V), a maximum amount of 8.3 A current is possible.
CAUTION
Pay attention to correct connecting:
Red connection: + terminal
Black connection: - terminal
14
MAINTENANCE
The machine is low-maintenance. It contains only a few parts, which have to be maintained
regularly by the operator. Malfunctions or defects that could impair the safety of the machine must
be repaired immediately.
WARNING
Hot surfaces and rotating machine parts while the engine is running can cause serious
injury or even death. Always stop the machine before carrying out any conversion,
adjustment, cleaning or maintenance work and secure it against unintentional
restarting and wait until the machine has cooled down
14.1
Maintenance-chart
Please maintain the generator in specified months or hours whatever comes first.
Before any
use
After 1. month or
after first 20
operating hours
After 3 month or
every 100
operating hours
After 6 month or
every 500
operating hours
Check tank, refuel if
necessary
О
Check engine oil level,
refill if necessary
O
Check for loss of fuel
or oil
O
Check for loose or
missing screws
O
O
Changing of oil
(O)
O
Changing of fuel
(O)
Cleaning the air filter
O
Cleaning the fuel filter
O
Check fuel line,
replace if necessary
O
Check battery
1 x every month
1. If used in dirty places, the generator should be maintained more regularly.
2.
If the user does not have the right tool, or has too little knowledge, maintenance should be
performed by a qualified person.
14.1.1
Engine oil change
NOTICE
Engine oil is toxic and must not be released into the environment! Follow the
instructions of the supplier and, if necessary, contact your local authorities
for information on proper disposal.
NOTICE
Changing the oil is easier when the engine is still warm.
•
Remove the oil outlet screw.