Before commisioning:
The log splitter is equipped with a hydraulic oil tank in the base plate.
CAUTION:
When not upright transport of the log splitter Oil can ent-soft through the bleed screw.
At low ambient temperatures, the hydraulic oil assumes a viscous consistency.
THEREFORE:
Especially at low ambient temperatures, a
minimum idle time of 3 minutes
must
be strictly observed
before each operation
!
Do not burden at this time the log splitter!
Lifting and lowering now about
10
to heat the slit assembly times without load to the hydraulic oil.
Failure to comply with this directive may result in damage to the hydraulic system and warranty is
excluded.
12.2.1
Checks before initial start-up
Checking the strength of all screw
Inspect the machine for concealed damage , eg by transport.
Verification of the electrical connection.
Make sure that the power is being protected circuit.
Make sure that will support the power, voltage and frequency of the motor of your power supply.
It must be a grounding available!
Electrical work may only be performed by trained specialist !
Make sure your extension cord does not overload the engine of your log splitter !
Extension cable must not be longer than 10m and its cross -section must not be less than 2.5
mm ². Only well-insulated , use appropriate extension cord for outdoor activity.
Search from the work under consideration of the safety regulations. Store the wood to be split
logs within reach . Creating the split logs from the work area.
Order before you edit the logs from exceeding the maximum length ( information, please refer
the technical data ) . If you want to split log with very thick diameter , it is recommended not to
exceed the maximum lengths . There are three different splitting length. Always choose the ap-
propriate height for each log length . Secure the table in the desired position always with the
locking device.
The supply cable so set that it can not be damaged ( by working ) .
Open the bleed screw. Turn the bleed screw a few turns on whenever you take the log splitter in
operation. Turn the bleed screw after operation completely .
Vent the hydraulic system. (see
12.1.5
)