Power Up Procedure
* NWI
When the device power on, the device will check is it already adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in every second and continue 3 minutes. Until timeout or the
device successful to inclusion by controller. The use can presses the
tamper key (or the circle button) 3 times to abort the NWI mode.
Play Sound
Using the SWITCH_BINARY_SET to play the siren, 0xFF will play the
emergency sound, 0x00 will stop to play.
The device also supports to receive the NOTIFICATION_REPORT to play
the different sound.
Notification Type
Event
Sound
Smoke Alarm (0x01)
0x01 ~ 0xFF
Fire Alert
Access Control (0x06)
Window/Door
Open (0x16)
Door Chime
Home Security (0x07)
0x01 ~ 0xFF
Emergency
Emergency Alarm (0x0A)
Contact Police
(0x01)
Police Car Sound
Emergency Alarm (0x0A)
Contact Fire
Service (0x02)
Fire Alert
Emergency Alarm (0x0A)
Contact Medical
Service (0x03)
Ambulance Sound
Over The Air (OTA) Firmware Update
The device support the Z-Wave firmware update via OTA.
Before starting the procedure, please remove the back cover of the
device. Otherwise the hardware check will be failed.
Let the controller into the firmware update mode, and then press the
front tamper key once to start the update.
After finish the firmware download, the LED will start flash in every 0.5
second. At that time,
please don't cut off the power
, otherwise it
will cause the firmware broken, and the device will no function.
After the LED stop flash, it is recommended that the user power up the
device.
Caution
: After power off the device, please wait about 30
seconds, and then re-plug the power line.
Security Network
The device support the security function. When the device included
with a security controller, the device will auto switch to the security
mode. In the security mode, the follow commands need using Security
CC wrapped to communicate, otherwise it will not response.
Note:
A “Security Enabled Z-Wave Controller” must be used in order to
fully utilize this function.
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_BASIC
Manual Battery Shutdown
When the DC power is dropped. The system will auto switch to use the
battery power. If you want to really shutdown the system, please follow
instructions as below.
1. Press and hold the circle button.
2. Click the tamper 3 times in 1.5 seconds.
3. Release the circle button.
3