Step 3 – Tap installation

Installation instructions

Cut a hole to suit your tap (35mm) 
in the sink or benchtop using a 
sheet metal hole punch or hole saw 

(not supplied).

3.2

Push spacer on to the base of the 
tap, with a light smear of silicone 
sealant on the underside of the 
spacer to ensure a watertight fit.

3.3

Position the tap so that water from 
the spout will fall into a sink/tray 
fitted with a drain

3.1

Pass the hoses down through the 
hole and locate the tap in place.

3.4

From below the benchtop, push 
the washer over the hoses and 
threaded rod, then push the spider 

clamp onto the threaded rod.
Check the tap is in the correct position, 

then secure the fastening nut.

3.5

Tap

Washer

Benchtop

Nut

Spider clamp

Spacer

For more detail, refer to installation instructions supplied with the tap.

The tap tube length permits installation of a tap 
height extension (not included).
For good fall of the water hoses, the tap tubes may 

be shortened using a PVC 
cutter (conduit cutter). 
Ensure the cut edges are 
not sharp, before fitting 
the hose.

3.6

Содержание UltraCare BCU40

Страница 1: ...1 807042 v1 00 03 21 HydroTap G5 UltraCare Install Instruct Model UltraCare BCU40 Installation Instructions Zip HydroTap G5 PRODUCTLABEL Visit our website to download the manuals Australia...

Страница 2: ...19 Cleaning 19 End of life disposal 19 Thank you for choosing Zip HydroTap Enjoy filtered boiling and chilled water from the Zip HydroTap The HydroTap Command Centre installed under the bench has a co...

Страница 3: ...ple portable socket outlets or portable power supplies at the rear of the appliance 8 Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the po...

Страница 4: ...technician To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson Venting Occasionally steam and or boiling water may discharge through a vent outlet on...

Страница 5: ...ses Classic tap shown part no 91519 BC chrome 1 x HydroTap Command Centre including water filter cartridge 1 x mains water braided hose part no 90056 Side Duct part no 91505 Vent Kit BC Model 1 x Inle...

Страница 6: ...ving jurisdiction The system is only designed to reduce normally occurring non pathogenic nuisance microorganisms Class B systems are not intended for treatment of contaminated water UltraCare BCU40 C...

Страница 7: ...are required The appliance must be connected to a potable water supply with min max working pressure as outlined in the Technical specifications with isolating valve within reach of the hose and posit...

Страница 8: ...Tap Command Centre Mains power supply to Command Centre Power for UV C Module Vent tray Side duct Mains water inlet isolation valve not supplied Step 1 Positioning Ensure there is adequate space in th...

Страница 9: ...out in cabinet oor Inlet vent options Fit the silicone door buffers to the inside edge of the cupboard door to provide an air space Step 2 Ventilation IMPORTANT Allow a minimum clearance envelope of...

Страница 10: ...ted with a drain 3 1 Pass the hoses down through the hole and locate the tap in place 3 4 From below the benchtop push the washer over the hoses and threaded rod then push the spider clamp onto the th...

Страница 11: ...Flush water supply lines before any plumbing connections are made to prevent sediment from affecting operation Connect electrical cable to the side of the Command Centre Power must remain OFF until co...

Страница 12: ...UE hose from tap Push at least 15mm over the fitting Connect USB C cable from UV C Module to HydroTap Ensure hose has constant fall Connect 12V power supply to HydroTap Power must remain OFF until com...

Страница 13: ...ection Push the hose over the connector for a minimum of 15mm There a constant fall from the tap down to the Command Centre Hoses must be trimmed to avoid loops and kinks Take care when positioning be...

Страница 14: ...filter factory setting With external filter Set bypass valve optional The bypass valve diverts the boiling feed water to external filtration optional internal filter is supplied with the unit The valv...

Страница 15: ...urn electrical power ON at both the power outlets 6 2 Step 6 Commissioning 10L bucket not supplied Open valve to let water flow Close valve when complete Do not commission your HydroTap until it is re...

Страница 16: ...ch requires the product to be flushed with fresh water at installation as shown on the Command Centre screen Each tank boiling and chilled must be emptied and filled three times For countertop font in...

Страница 17: ...p Service Cold sensor Closed Internal fault Call Zip Service Flood sensor Open Internal fault Call Zip Service Condenser sensor Closed Internal fault Check Ventilation Call Zip Service Condenser senso...

Страница 18: ...ools down and reports that its internal temperature has returned to 40 C or lower UV Under Current Tried to dispense cold water and current of UV C Module not at minimum threshold a The 12V external p...

Страница 19: ...help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details End of life disposal In Australia Zip offers a full...

Страница 20: ...efer to User Guide for operation and maintenance ZipWater Australia PtyLtd ABN46000578727 67 77AllinghamStreet CondellParkNSW2200 Postal LockedBag80 Bankstown1885 Australia Tel 612 97963100 Freecall18...